071
4.1 Function Code
FE Group - Panel Function Setting and Parameter Management
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
FE.00 LCD language option
(only for LCD panel)
0: Chinese
1: English
2: reserved
1
0
○
FE.01 Key M-FUNC function
0: JOG (jog control)
1: FWD/REV switch
2: clear frequency set by
▲ / ▼
3: switch between local
operation and remote
control (reserved)
4: reverse
1
0
×
FE.02 Key STOP/RST function
0: only effective to panel
control
1: effective to both panel
and terminal control
2: effective to both panel
and communication
control
3: effective to all control
modes
1
3
○
FE.03 STOP+RUN emergency
stop
0: disabled
1: coast to stop
1
1
○
FE.04 Close-Ioop display factor 0.01 ~ 100.00
0.01
1.00
○
FE.05 Display factor of load
rotating speed
0.01 ~ 100.00
0.01
1.00
○
FE.06 Line speed factor
0.01 ~ 100.00
0.01
1.00
○
FE.07 Encoder regulation speed
(served)
1 ~ 100
1
70
○
FE.08
Monitoring parameter
selection 1 in operation
status
0 ~ 57
1
0
○
FE.09
Monitoring parameters
selection 2 in operation
status
0 ~ 57
1
5
○