155
5.3 Functions of other Register Address:
function
address
description
VFD operation
status
A000H(1A00H)
byte bit
meaning
Byte1
Bit7
0: no action
1: overload pre-alarm
Bit6 ~ Bit5
0: INV_220V
1: INV_380V
2: INV_660V
3: INV_1140V
Bit4
0: no action
1: power off save
Bit3
0: no action
1: reset
Bit2 ~ Bit1
0: no action
1: static tuning
2: dynamic tuning
Bit0
0: control panel mode
I : terminal control mode
2: communication control mode
3 : reserved
Byte0 Bit7
VFD operation
status
A000H(1A00H) Byte0
Bit6
0: no action
1: bus voltage is normal
Bit5
0: no action
1: undervoltage
Bit4
0: no action
1: jog run
Bit3
0: forward
1: reverse
Bit2 ~ Bit1
1: Acc
2: Dec
3 : constant speed
Bit0
0: stop status
1: run status
Read VFD fault
code
E000H(1E00H) Address E000H and 1E00H interchangeable (refer to fault
code table and example of read function code 03H)
Read VFD fault
pre-alarm code
E001H(1E01H) Address E001H and 1E01H interchangeable (refer to example
of pre-alarm code, read function code 03H)
User password
check
AD00H(1C00H) Address AD00H and 1C00H interchangeable (refer to
example of write function code 06H)
Operation limit
password check AD01H(1C01H)
Address AD00H and 1C00H interchangeable (refer to example
of write function code 06H)
Communication Protocol
Содержание SKI600
Страница 3: ......
Страница 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Страница 179: ......
Страница 180: ......