032
4.1 Function Code
F0 Group - Basic Run Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F0.10 Digital set 1 control
LED ones digit: power down
storage
0: storage
1: not storage
LED tens digit: hold when stop
0: hold
1: not hold
LED hundred digit: ▲ / ▼ key,
UP/DOWN frequency
0: invalid
1: valid
LED thousands digit: reserved
1
000
○
F0.11 Digital set 2 control
1
000
○
F0.12 Frequency source
digital setting 1
0.00Hz ~【F0.16】upper limit
of frequency
0.01Hz
50.00
○
F0.13 Frequency source
digital setting 2
0.00Hz ~【F0.16】upper limit
of frequency
0.01Hz
50.00
○
F0.14
Auxiliary frequency
source weight
coefficient K setting
0.01 ~ 10.00
0.01
1.00
○
F0.15 Maximum output
frequency
Low frequency range: MAX
{50.00, 【F0.16】}~ 300.00
High frequency range: MAX
{50.00, 【F0.16】}~ 3000.0
0.01Hz
50.00
×
F0.16 Upper limit
frequency
【F0.17】~【F0.15】
0.01Hz
50.00
×
F0.17 Lower limit
frequency
0.00Hz ~【F0.16】
0.01Hz
0.00
×
Содержание SKI600
Страница 3: ......
Страница 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Страница 179: ......
Страница 180: ......