TOPEX Bytton (HSPA+ / LTE)
ByttonLTE(full)_genericUsermanual_sw306FAS_revN.1.docx
Page: 235 / 290
Parameters for the serial connection
Here you can set the usual parameters for a RS-232 serial connection,
such as speed in bits per second (1200, 9600, 115200 etc), number of
Data bits (8, 7, 5 etc) per byte , number of Stop bits, parity checking
(Not used, Even or Odd), flow control (Not used, Xon-Xoff, Hardware).
Current recommended settings are 9600 bps, 8-N-1.
Figure 5-189: parameters for the serial connection(s)
.
Different port configurations
If your Bytton LTE has two RS-232 ports, they can be configured with
different parameters, according to the requirements of the particular serial
connection to the respective legacy equipment.
Remote connection parameters
In case of using the remote serial server, you must fill-in additional parameters for this feature
Delay
, the
value, in milliseconds, of the buffers that stores the characters before sending them over the serial
connection,
Packet Size
, in bytes (default value 500) and
Server x Port
, the number of the IP port used for the
remote serial connection.
See below a few examples of serial parameters configuration:
Figure 5-190: Examples of remote connection parameter settings for the serial link
.