5.6.5 SMS
Depending upon the actual firmware version, your equipment may have or not this menu item. With
SERVICES>SMS”, Bytton LTE implements a feature for remote administration and reporting via SMS:
Figure 5-191: Settings for SMS services
.
Service SMS
: select Enable to activate this feature. By default it is disabled.
Phone No
.: enter a full mobile telephone number such as 074199….. in the above example, or just a
prefix, “0741” or “075”. Only text messages issued from this number or prefix will be taken into account!
Figure 5-192: Establishing parameters for the SMS managemnt service
.
SMS text
: enter here a word that will act as password.
Time to read
: time period, in seconds, for Bytton LTE to check for SMS messages.
In the System>Log you will see the testing for received SMS messages upon corresponding intervals:
Jul 6 10:07:01 bytton cron.err crond[3442]: USER root pid 5971 cmd net_moni
Jul 6 10:07:05 bytton user.info pbx: test AT OK/NOK
Jul 6 10:07:06 bytton user.info pbx: sms len=2401
Jul 6 10:07:14 bytton user.info pbx: test AT OK/NOK