TROUBLESHOOTING
DEFINITION
FUNCTION
Photoeyes
The photoeyes are wired to the 24VDC circuit and are wired as normally closed when there is power to the unit and the emitter
photoeye is aligned with the receiver photoeye There are 3 lights on the receiver and 1 on the emitter Green is for power,
yellow and orange are for proper alignment The photoeyes will reverse or hold the door open when the photoeye beam is
blocked When the beam is not broken, the door will auto-reclose If photoeyes require adjustment, check that lower tracks are
square to the wall
a Power to brown (DC) and blue (OV) wires
b Internal photoeye relay (wires black/blue) should be closed when photoeye is aligned and open when not aligned
c When open, i-COMM 3 verifies photoeye inputs are off If on, door will fault If off, test is ok and emitters turn on
d Orange and yellow light on the Receiver should be on when aligned
e Green light on the Emitter indicates the unit is powered up
f Input X11 will go off when the upper 54in [137m] photoeye is tripped
g Input X10 will go off when the lower 18in [457mm] photoeye is tripped
h If 2 or more doors are back to back, verify they are not reading each other A plate may be required to separate
Power Supply
Power Supply is powered by 120VAC from the F7 fuse and delivers 24VDC to the i-COMM 3
Pressure
If the curtain is blowing out because of high wind or negative pressure, check the following:
a Lower tracks MUST be mounted at ODW + 1/2in [13mm]
If mounted wider, excessive curtain wear may occur If too narrow, curtain buckling or billowing will be greater
b Check to make sure the curtain has all the drive spheres in place
c Verify Lexan Strips are present and functioning properly
Virtual Vision
Virtual Vision is optional on the FasTrax XL door When motion is sensed via Falcon motion sensors, the Virtual Vision red
LEDs will illuminate to notify driver of movement on the opposite side of the curtain
a It is normal for the YDC1 output to flash on i-COMM 3 during door operation
Voltage Change
To change the voltage:
a Change transformer taps and fuses per electrical diagram
b Change motor wiring per junction box diagram
c Replace Inverter with proper voltage
d Replace Brake Resistor with proper voltage
e Change voltage selection on i-COMM 3
Содержание FasTrax XL
Страница 9: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 9...
Страница 89: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 89...
Страница 90: ...FasTrax XL Installation Service Owner s Manual Rite Hite 90 Publication AMEN00316 2020 07 06...
Страница 91: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 91...