FasTrax
®
XL
Installation/Service/Owner's Manual
Rite‑Hite
®
28
Publication:
AMEN00316 2020-07-06
INSTALLATION
Primary/Curtain Tube Centering
NOTICE
DO NOT
tighten set screws into the keyway slot
Set screws are not long enough to provide a tight
connection Shaft failure may result
A
B
1 After the curtain tube and header braces are installed,
center the primary tube between the header lower
tracks
2 Measure from inside header plate to face of the
curtain tube plate Tighten bearing set screws (A)
when the
Critical Centering Dimension is:
0844in [21mm]
3 Slide lock collar (B) next to bearing and tighten lock
collar set screws
Figure 41