FasTrax
®
XL
Installation/Service/Owner's Manual
Rite‑Hite
®
42
Publication:
AMEN00316 2020-07-06
INSTALLATION
Electrical
DANGER
Per local electrical codes, when working with
electrical or electronic controls:
•
Power source must be locked out and marked
•
A qualified electrician should install the wiring
Selon les codes électriques locaux, lorsque vous
utilisez des commandes électriques ou
électroniques:
•
La source d'alimentation doit être verrouillée et
marquée
•
Un électricien qualifié doit installer le câblage
DANGER
To reduce risk of injury or death, an earth ground
connection must be made to the green/yellow
control box ground terminal.
If metal conduit is used as the ground connector,
a ground bushing and green/yellow wire must be
properly attached to the conduit for connection to
the ground terminal, per local electrical codes.
Pour réduire le risque de blessures ou de décès,un
raccordement de terre doit être fait à la boite de
contrôle verte/jaune de la borne de terre.
Si le connecteur de terre utilisé est un conduit
métallique, un manchon de mise à la terre et un
câble vert/jaune doivent être correctement fixés au
conduit un raccordement à la borne de terre, par
codes électriques locales.
NOTICE
DO NOT
drill holes on top of control box to run
conduit, as dust particles and moisture may cause
damage to electrical components The safest location
is at the bottom Failure to do so will void warranty
General
1 It is the responsibility of the end user to provide
electrical service up to the control box with proper
branch service protection and an approved means
of disconnect
2 20 or 30 Amp service may be required for cable runs
longer than 300ft [91m]
3 If local electrical codes require the use of rigid
conduit: Remove conduit connector, control cables
from the flexible conduit and install the rigid conduit in
its place and rewire
4 Mount control box adjacent to the door at
approximately 14in [356mm] from lower track
5 If possible mount on the warm side regardless of door
mount side
6 All holes drilled through the control box must be
through the bottom of the box Conduit entering the
sides or top of the enclosure will void the warranty
7 Use the proper sealed connectors to maintain the
NEMA rating on the enclosure
8 Incoming 3-phase power must connect into fuse
holder terminals F1, F2, F3 and ground terminal
Terminals in the control box will not accommodate
wires larger than 12AWG [205mm]
9 Route all field installed wires so that separation
is maintained between line voltage wires and low
voltage class II wiring
10 The control box is provided with class CC protective
fusing for the incoming power
11 Clamp conduit to wall after complete
12 The control box cable is pre-wired to the control box
Attach control box cable to the conduit mounting
bracket on the gearbox Connect motor, brake cables
and fasten terminal strip to the motor junction box
If the flexible conduit is too long, unwire control box
cable wires and cut the protective outer casing the
required amount
DO NOT
coil or let conduit hang on
the floor
13 In freezer, cooler, and exterior applications where
a conduit passes from a warm to cold temperature
zone, the conduit must be plugged with epoxy This
will help prevent condensation from forming in the
conduit For more information, see Section 300-7a
of the National Electric Code
14 Refer to electrical diagrams for this door for further
information
NOTE:
DO NOT
splice control wiring
Содержание FasTrax XL
Страница 9: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 9...
Страница 89: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 89...
Страница 90: ...FasTrax XL Installation Service Owner s Manual Rite Hite 90 Publication AMEN00316 2020 07 06...
Страница 91: ...Rite Hite Installation Service Owner s Manual FasTrax XL Publication AMEN00316 2020 07 06 91...