Fuse / Breakers
It is recommended that you fit
a thermal breaker or fuse at
the distribution panel.
The suitable fuse rating
for the thermal breaker is
dependent on the number of
devices you are connecting. If
in doubt consult an authorized
Raymarine dealer
Power consumption
Full brightness:
•
a75
— 7.7 W Max
•
a77
— 13.2 W Max
•
a78
— 9.9 W Max
PowerSave mode:
•
a75
— 3.1 W Max
•
a77
— 8.2 W Max
•
a78
— 5.2 W Max
Note:
Power
consumption figures
represent a loaded
system; for sonar variants
this includes an active
600 W transducer and
DownVision
™
variants
includes an active
CPT-100
transducer.
LEN
(Refer to Seatalk
ng
reference manual for further
information).
1
a9x Power specification
Nominal supply voltage
12 V / 24 V dc
Operating voltage range
10.8 V dc to 31.2 V dc
In-line Fuse
• 7 A (Standard 20 mm glass
fuse)
Power consumption
Full brightness:
•
a95
— 13.8 W Max
•
a97
— 15.1 W Max
•
a98
— 15 W Max
PowerSave mode:
•
a95
— 5.0 W Max
•
a97
— 7.3 W Max
•
a98
— 5.7 W Max
LEN
(Refer to Seatalk
ng
reference manual for further
information).
1
Note:
Power consumption figures represent a
loaded system; for sonar variants this includes
an active 600 W transducer and
DownVision
™
variants includes an active
CPT-100
transducer.
a12x Power specification
Nominal supply voltage
12 V / 24 V dc
Operating voltage range
10.8 V dc to 31.2 V dc
In-line Fuse
• 7 A (Standard 20 mm glass
fuse)
Power consumption
Full brightness:
•
a125
— 23 W Max
•
a127
— 23.9 W Max
•
a128
— 24.3 W Max
PowerSave mode:
•
a125
— 5.2 W Max
•
a127
— 7.4 W Max
•
a128
— 6.7 W Max
LEN
(Refer to Seatalk
ng
reference manual for further
information).
1
Note:
Power consumption figures represent a
loaded system; for sonar variants this includes
an active 600 W transducer and
DownVision
™
variants includes an active
CPT-100
transducer.
Environmental specification
Environmental specifications below apply to all
display variants
Operating temperature
-25 ºC to +55 ºC (-13 ºF to
131 ºF)
Storage temperature
-30 ºC to +70 ºC (-22 ºF to
158 ºF)
Relative humidity
Maximum 75%
Waterproof rating
• IPX6 and IPX7
• IPX6 (e165 only)
Viewing angle
000
000
000
000
000
00000
00000
00000
D
12576-1
C
D
A
B
a6x
a7x
a9x
a12x
A
(Right)
60º
75º
80º
80º
B (Left)
60º
75º
80º
80º
C (Up)
60º
70º
80º
80º
D
(Down)
50º
75º
80º
80º
Technical specification
425
Содержание c125
Страница 2: ......
Страница 14: ...14 a Series c Series e Series ...
Страница 41: ...13 GPS receiver 14 Thermal camera 15 Wireless connection Planning the installation 41 ...
Страница 48: ...48 a Series c Series e Series ...
Страница 80: ...80 a Series c Series e Series ...
Страница 118: ...118 a Series c Series e Series ...
Страница 184: ...184 a Series c Series e Series ...
Страница 185: ...Chapter 13 Man Overboard MOB Chapter contents 13 1 Man overboard on page 186 Man Overboard MOB 185 ...
Страница 188: ...188 a Series c Series e Series ...
Страница 191: ...Chapter 15 Fuel manager Chapter contents 15 1 Fuel manager overview on page 192 Fuel manager 191 ...
Страница 206: ...206 a Series c Series e Series ...
Страница 228: ...228 a Series c Series e Series ...
Страница 290: ...290 a Series c Series e Series ...
Страница 310: ...310 a Series c Series e Series ...
Страница 340: ...340 a Series c Series e Series ...
Страница 374: ...374 a Series c Series e Series ...
Страница 422: ...422 a Series c Series e Series ...
Страница 436: ...436 a Series c Series e Series ...
Страница 462: ...462 a Series c Series e Series ...
Страница 463: ......
Страница 464: ...www raymarine com ...