• 00.00 to 23:59 hrs (hh:mm)
Countdown Timer
When enabled, counts down the time period specified
in the
Timer Period
setting, and triggers an alarm
when zero is reached.
Enable
:
• Enabled (Ticked)
• Disabled (Un-ticked) (default)
Time Period
• 00:00:01 to 99:59:59 (hh:mm:ss)
Fishing — shallow
water arrival
When enabled, an alarm is triggered when the depth
reaches the value specified in the
Shallow Limit
alarm
setting. This option is only available when current
depth data is available.
Note:
The
Shallow Limit
cannot be set to a depth
greater than the depth specified for the
Deep Limit
setting.
.
Enable
:
• Enabled (Ticked)
• Disabled (Un-ticked) (default)
Shallow Limit
Default values:
• 1.5 m / 5.0 ft / 0.89 fa (default)
Range:
• 0.6 m to Max depth limit of connected sonar
module
• 2 ft to Max depth limit of connected sonar
module
• 0.3 fa to Max depth limit of connected sonar
module
Fishing — deep
water arrival
When enabled, an alarm is triggered when the depth
reaches the value specified in the
Deep Limit
alarm
setting. This option is only available when current
depth data is available.
Note:
The
Deep Limit
cannot be set to a depth
less than the depth specified for the
Shallow Limit
setting.
.
Enable
:
• Enabled (Ticked)
• Disabled (Un-ticked) (default)
Deep Limit
Default values:
• 1.5 m / 5.0 ft / 0.89 fa (default)
Range:
• Shallow Limit to 914 m
• Shallow Limit to 3,000 ft
• Shallow Limit to 500 fa
Water temperature
When enabled, an alarm is triggered when:
• the water temperature is equal to or less than the
temperature specified in the
Lower Temp Limit
setting, or
• the water temperature is equal to or greater than the
temperature specified in the
Upper Tempo Limit
setting.
Enable
:
• Enabled (Ticked)
• Disabled (Un-ticked) (default)
Upper Temp Limit
Defaults:
• 23.9°C / 75°F (default)
Range:
• Lower Temp Limit to 37.7°C
• Lower Temp Limit to 99.9°F
Lower Temp Limit
Defaults:
• 15.6°C / 60°F (default)
Range:
• –23.3°C to Upper Temp Limit
Alarm management
181
Содержание c125
Страница 2: ......
Страница 14: ...14 a Series c Series e Series ...
Страница 41: ...13 GPS receiver 14 Thermal camera 15 Wireless connection Planning the installation 41 ...
Страница 48: ...48 a Series c Series e Series ...
Страница 80: ...80 a Series c Series e Series ...
Страница 118: ...118 a Series c Series e Series ...
Страница 184: ...184 a Series c Series e Series ...
Страница 185: ...Chapter 13 Man Overboard MOB Chapter contents 13 1 Man overboard on page 186 Man Overboard MOB 185 ...
Страница 188: ...188 a Series c Series e Series ...
Страница 191: ...Chapter 15 Fuel manager Chapter contents 15 1 Fuel manager overview on page 192 Fuel manager 191 ...
Страница 206: ...206 a Series c Series e Series ...
Страница 228: ...228 a Series c Series e Series ...
Страница 290: ...290 a Series c Series e Series ...
Страница 310: ...310 a Series c Series e Series ...
Страница 340: ...340 a Series c Series e Series ...
Страница 374: ...374 a Series c Series e Series ...
Страница 422: ...422 a Series c Series e Series ...
Страница 436: ...436 a Series c Series e Series ...
Страница 462: ...462 a Series c Series e Series ...
Страница 463: ......
Страница 464: ...www raymarine com ...