R&S AFQ100A
AFQ Commands - Signal Generation
1401.3084.32 6.49
E-3
[SOURce:]EQUalizer:IQ:CATalog?
This command lists all files containing I/Q equalizer data tables saved on local hard disk. This
command reads out the subdirectories and files in the specified directory. The default directory is set
using command
MMEM:CDIRectory
.
The command is a query command and therefore has no *RST value.
Example:
MMEM:CDIR 'd:/user/Equalizer'
'sets the default directory
EQU:IQ:CAT?
'lists all files containing I/Q equalizer data tables.
*RST value
Resolution
Options
SCPI
-
-
Device-specific
[SOURce:]EQUalizer:IQ:DELete
<FILE NAME>
This command deletes the selected I/Q equalizer data table from local hard disk.
The command triggers an event and therefore has no query form and no *RST value.
Example:
EQU:IQ:SEL "iqdata_1"
'selects the file 'iqdata_1.afq_iq_fgp' to be deleted.
EQU:IQ:DEL "iqdata_1"
'deletes the file 'iqdata_1.afq_iq_fgp' from HD.
*RST value
Resolution
Options
SCPI
-
-
Device-specific
[SOURce:]EQUalizer:IQ:I:FREQuency
0 ... 1 GHz
This command enters frequency values into the current data table of the I path selected using the
EQU:IQ:I:SEL command.
Example:
EQU:IQ:I:FREQ 10000,20000,30000
'writes three frequency values into the current data table.
*RST value
Resolution
Options
SCPI
-
1 Hz
Device-specific
[SOURce:]EQUalizer:IQ:I:GAIN
-5 ... +50 dB
This command enters gain values into the current data table of the I path.
Example:
EQU:IQ:I:GAIN 0,-5,-3
'writes three gain values into the current data table.
*RST value
Resolution
Options
SCPI
-
0.001 dB
Device-specific