R&S AFQ100A
Baseband Block
1401.3084.32 4.22
E-3
Repeat N Times
Run Mode "
Repeat N Times
"
The next segment starts to be output after a
segment trigger event. After finishing the
waveform the instrument switches to the idle
mode. A regular trigger event restarts signal
generation. Signal generation is repeated as
often as the
Repeat Count
for the waveform is
set (see
Then signal generation stops.
Remote-control command:
SOUR:TRIG:SEGM:MODE REP
Repeat Count -
Segment Trigger
(Segment mode Repeat N Times only)
Sets the repeat rate for each particular segment of a multisegment
waveform. The repeat count is entered in a list of numbers, separated
by semicolons. Each segment can be repeated up to 100 times.
Remote-control command:
SOUR:TRIG:SEGM:RCO 1;1;3;1;4...
Source - Segment
Trigger
Selects the segment trigger source of a multi segment waveform.
Manual
The segment trigger event is executed by clicking
Execute
.
Remote-control command:
SOUR:TRIG:SEGM:SOUR MAN
External
The segment trigger event is executed with the
aid of the active edge of an external trigger
signal. The trigger signal is fed in via the NEXT
connector. The active edge is selected under
Slope
.
Remote-control command:
SOUR:TRIG:SEGM:SOUR EXT