R&S AFQ100A
Baseband Block
1401.3084.32 4.31
E-3
Current Range
Without Recalculation
- Marker
Displays the dynamic range within which the delay of the marker
signals can be set without restarting the marker and signal.
Remote-control command:
SOUR:TRIG:OUTP2:DEL:MAX?
SOUR:TRIG:OUTP2:DEL:MIN?
Fix Delay to Current
range - Marker
Selecting this check box restricts the marker delay setting range to the
dynamic range. In this range the delay can be set without restarting
the marker and the signal.
Remote-control command:
SOUR:TRIG:OUTP:DEL:FIX ON
Clock Dialog
The
Clock
dialog is used to select and configure the clock source. The
Clock
dialog is accessed via the
Baseband
block.
To enable a very precise simultaneous signal output of several connected R&S AFQs, a special
synchronization mode can be selected in the
Reference Clock
area (see also following section
Up Several Connected R&S AFQs for Precise Simultaneous Signal Output
on page 4.36).
Note:
The clock signal also triggers the output signal for digital output on PORT 2 (see section
Digital
Output
, on page 4.61).