R&S AFQ100A
AFQ Commands - Signal Generation
1401.3084.32 6.11
E-3
[SOURce:]TSIGnal:TSINe[1|2]:PERiods
1 ... 50
The command sets the number of periods for the sine waves. The values are set separately for
each component of the test signal.
Example:
TSIG:TSIN1:PER 4
TSIG:TSIN2:PER 6
'sets the number of periods of sine wave 1 to 4 and
the number of periods of the second sinewave to 6.
*RST value
Resolution
Options
SCPI
4
Device-specific
[SOURce:]TSIGnal:TSINe[1|2]:PHASe
-360 ... 360 degree
Sets the phase shifts of the sine waves. The values are set separately for each sine wave of the test
signal.
Example:
TSIG1:TSIN1:PHAS 360
TSIG2:TSIN2:PHAS -360
'sets the phase offset of the I channel to 360 degree and
the phase offset of the Q channel to -360 degree.
*RST value
Resolution
Options
SCPI
0
Device-specific
[SOURce:]TSIGnal:RECT:AMPLitude
0 ... +1 FS
The command sets the digital amplitude of the rectangular wave. The abbreviation FS means full
scale.
Example:
TSIG:RECT:AMPL 0.5
'sets the amplitude to 0.5 FS.
*RST value
Resolution
Options
SCPI
0.8
Device-specific
[SOURce:]TSIGnal:RECT:CREate
The command generates a waveform which is output directly.
This command triggers an event and therefore has no *RST value and no query form.
Example:
TSIG:RECT:CRE
'a signal is generated and output directly.
*RST value
Resolution
Options
SCPI
-
Device-specific