R&S AFQ100A
Baseband Block
1401.3084.32 4.14
E-3
When retrigger is enabled the current signal output
is reset at a trigger during signal generation.
Remote-control command:
SOUR:TRIG:MODE SING
Repeat N
Times
Multiple output of the waveform when a trigger event
occurs.
Note:
Run mode Repeat N Times is enabled only in
combination with Segment Trigger source
Auto
(see "
Source - Segment Trigger
", on page 4.22).
If Segment Trigger source is set different to
Auto
, the instrument operates in run mode
Continuous
.
Retrigger "Off"
When retrigger is disabled a trigger during signal
generation is without effect:
Retrigger "On"
When retrigger is enabled the current signal output
is reset at a subsequent trigger event after start of
signal generation.
The waveform is repeated as often as the number of
Repeat Count
on page 4.34). After finishing the last run signal
generation stops.
The waveform output can be restarted by
retriggering or, switching off and then switching on
the ARB state in the baseband block.
Remote-control command:
SOUR:TRIG:MODE REP