FASTRAK MANUAL
Rev. G
89
JUNE 2012
10. Command Error
Command errors are defined as follows:
COMMAND ERROR
RECORD IDENTIFIER ........ *
INITIATING COMMAND ....... all invalid commands
byte(s)
Identification
Format
1 ...
Record Type, “2”
A1
2 ...
Blank
A1
3 ...
Sub-record type ‘E’
A1
4-10 ...
“*ERROR*”
11-?? ...
Erroneous command as it was input
??-+11...
“*ERROR* EC”
??-?? ...
Error code from following list:
-1 Required field missing
-2 Required numeric is non-numeric
-3 Value is outside required range
-4 Specified frequency not hardware configured
-5 Internal buffer limits exceeded
-99 Undefined input - cannot identify command
??-+3 ...
“*PS” (position)
??-?? ...
Character position in the input record -
note numbering starts 0,1,2...
??-+3 ...
“*FL” (field)
??-?? ...
Field number causing the error - note
numbering of the field is 0,1,2... and
starts at ‘0’ following the command identifier.
??-+3 ...
“*ST” (station)
??-?? ...
Number of the affected system station less 1;
i.e., this value ranges from 0-3, stations are
numbered in commands as 1-4.