User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
53
/
143
The
limit
range
is
calculated
using
the
scale
factor
and
the
offset
value
in
System
configuration
–
General.
Max.
input
value
x
Scale
+
Offset
=
Limit
range
The
max.
input
value
is:
In
analogue
inputs:
20
mA
In
frequency
inputs:
1000
Hz
Example
:
Analogue
connection
1
Scale
factor
=
5,0
Offset
value
=
‐
1,0
Limit
range
=
20
x
5,0
+
1,0
=
101,0
The
limit
range
is
then
0,0
–
101,0
Example:
Frequency
connection
1
Scale
factor
=
0,6
Offset
value
=
1,0
Limit
range
=
1000
x
0,6
–
1,0
=
559,0
The
limit
range
is
then
0,0
–
559,0
A
negative
offset
value
must
be
added.
A
positive
offset
value
must
be
deducted.
NOTE:
Never
enter
the
offset
value
as
the
limit
value.
The
smallest
changes
would
then
cause
the
irrigation
program
to
be
stopped
by
the
weather
station.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...