User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
33
/
143
7.2.2
Example
of
Program
End
with
Last
running
and
Interval
Pumps
1,
3,
and
5
are
installed
and
active.
Last
running:
50
seconds
Interval:
20
seconds
Program
ends,
all
valves
are
closed,
all
pumps
continue
to
run.
Last
running
runs
next.
Pump
1
stop
after
Last
running
expires.
The
pump
with
the
lowest
number
is
always
switched
off
first
.
The
interval
runs
now.
Pump
3
stops
after
the
interval
expires.
The
interval
runs
again.
Pump
5
stops
after
the
interval
expires.
Seconds
Operation
0
Last
valve
closes
30
(Last
running)
Pump
1
stop
(Relay
1
is
deenergised.)
50
(Interval)
Pump
3
stops
70
(Interval)
Pump
5
stops
In
this
case
the
last
pump
stops
70
seconds
after
the
last
valve
has
closed.
The
Relay
1
and
2
outputs
are
deenergised
on
the
stopping
of
Pump
1
and
2.
In
this
example
Relay
1
output
will
be
deenergised
after
30
seconds.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...