User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
45
/
143
7.6.3
Minimum
pump
run
time:
(SPECIAL
FUNCTION)
The
minimum
pump
run
time
will
be
entered
in
this
field.
This
avoids
a
permanent
start/stop
(in
short
intervals)
of
the
pumps.
This
function
is
just
active
if
irrigation
programs
(automatic
or
manual
start)
are
active.
Input
range:
15
–
60
sec.
(only
3
sec.
Steps
allowed)
Standard:
15
sec.
7.6.4
Interval
time
to
calculate
the
flow:
(SPECIAL
FUNCTION)
During
an
irrigation
program
the
optimum
pump
sequence
will
be
determined
depending
on
the
current
calculated
flow.
Through
this
the
influences
of
a
variable
flow
will
be
reduced.
It
creates
an
optimal
pump
sequence,
determined
by
the
integrated
average
flow
calculation.
This
represents
the
time
how
often
in
the
irrigation
cycle
the
average
should
be
calculated,
depending
on
the
current
flow
of
the
valve.
The
60
sec.
flow
of
the
valve
is
the
decisive
factor
for
an
optimal
pump
sequence,
depending
of
the
average
value
in
the
last
60
sec.
Standard:
0
sec.
7.6.5
Maximum
retention
time
to
open
the
valves
(ONLY
FOR
BI
‐
DIR
‐
DECODER)
This
time
represents
how
many
seconds
the
system
accepts
the
status
„
valve
closed
“
until
an
error
message
will
be
created,
if
a
decoder
will
be
activated.
This
function
asked
for
the
status
of
the
flow
sensor,
if
a
decoder
will
be
activated.
7.6.6
Maximum
retention
time
to
close
the
valves
(ONLY
FOR
BI
‐
DIR
‐
DECODER)
This
time
represents
how
many
seconds
the
system
accepts
the
status
„
valve
closed
“
until
an
error
message
will
be
created,
if
a
decoder
will
be
activated.
This
function
asked
for
the
status
of
the
flow
sensor,
if
a
decoder
will
be
activated.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...