User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
129
/
143
Options:
[1]
Reset
VCU
error
Use
this
function
to
resets
the
VCU
after
an
error
has
occurred.
The
decoder
line
will
be
initialised.
This
function
must
be
executed
after
an
error
has
occurred.
Otherwise
irrigation
is
impossible.
[2]
Close
all
manual
open
valves
Use
this
function
to
close
all
manually
open
valves.
Last
command
Your
last
command
is
always
shown
here.
15.
Decoder
15.1
Programming
of
Decoder
Attention:
Only
in
Password
level
3
!
Before
a
new
decoder
is
installed
an
address
(number)
must
be
programmed
into
it.
Decoder
numbers
1
‐
240
are
reserved
for
valves.
Only
these
numbers
can
be
activated
by
an
irrigation
program.
The
pump
decoders
have
the
following
numbers:
246
‐
Pump
1
247
‐
Pump
2
248
‐
Pump
3
249
‐
Pump
4
250
‐
Pump
5
Decoder
no.
245
is
only
for
the
supervising
of
the
pump
station.
Please
be
aware,
that
the
pump
manger
always
starts
the
pump
decoder
with
the
highest
number
first.
Decoder
251
and
252
are
reserved
for
the
special
function
of
the
frequenz
2
[weather
station].
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...