User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
128
/
143
14.4.7
Service
Menu
05
Two
different
service
functions
are
available
in
this
menu.
PERROT
REGNERBAU
REMOTE
TERMINAL
‐
SERVICE
16.01.12
13:02:19
VCU
Status
:100
‐
No
error
[1]
‐
Reset
VCU
error
[2]
‐
Close
all
manual
open
valves
Last
command:
[2]
‐
close
all
manual
open
valves
The
VCU
Status
field
indicates
the
current
status
of
the
decoder
line.
The
following
messages
can
be
displayed:
100
‐
No
Error
No
error
has
been
detected.
101
‐
Line
init
If
this
message
shows
up
the
decoder
line
is
being
initialised.
Once
the
initialization
is
finished
a
message
follows.
100
to
105.
102
‐
Sync
error
The
decoder
line
cannot
be
synchronised.
Contact
a
Perrot
representative
near
you.
103
‐
Ground
error
The
earth
current
in
the
decoder
cable
is
too
high.
Check
the
decoder
cable
for
defects.
(Cable
connections,
etc.)
104
‐
Load
error
The
current
consumption
of
the
decoder
line
is
too
high.
Check
the
decoder
line
for
short
‐
circuits
and
check
the
decoder
itself.
105
‐
Volt
error
The
output
voltage
of
the
decoder
line
is
too
low.
Contact
a
Perrot
representative
near
you.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...