Code:054
‐
Pump
flow
leak
The
message
appears
only
when
a
flow
meter
has
been
installed.
Check
the
pressure
pipes
and
all
valves
for
leaks.
Code:055
‐
Decoder
test
is
running,
stop
test
For
your
information
only.
Code:056
‐
Download
active,
stop
download
Code:057
‐
Not
enough
free
disk
space
There
is
not
enough
free
storage
space
on
your
disk.
Delete
the
programs
or
files
you
no
longer
need.
Code:058
‐
Error
during
backup
sequence
Code:059
‐
file
"%s"
is
missing
on
restore
disk
Call
the
service
engineer.
Code:060
‐
Port
not
available
to
remote
transmitter,
change
settings
Code:061
‐
Step"%s"
No
step
time
You
have
not
entered
step
time
for
a
step
in
the
Manual
program
menu.
Code:062
‐
Printer
not
installed
You
want
to
but
there
is
no
printer
installed.
Install
a
printer
under
Windows.
100
‐
No
error
Decoder
line
status.
101
‐
Line
init
Decoder
line
is
being
initialised.
Connection
to
decoders
is
being
established.
102
‐
Sync
error
The
power
supply
of
230
V
/
50
Hz
is
not
synchronised.
Restart
the
VCU.
103
‐
Ground
error
The
earth
current
is
too
high.
Check
the
decoder
cable
for
damaged
insulation,
valve
boxes
for
water
flooding,
etc.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...