User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
32
/
143
7.2.1
Example
of
Pump
Start
with
Forerunning
and
Interval
Pumps
1,
3,
and
5
are
installed
and
active.
Forerunning:
50
seconds
Interval:
20
seconds
Program
start,
Pump
5
starts
at
the
same
time
The
pump
with
the
highest
number
starts
always
first
.
The
interval
entered
runs
next.
Pump
3
starts
after
the
interval
expires.
The
interval
runs
again.
Pump
1
starts
after
the
interval
expires.
Now
Forerunning
runs.
The
first
valve
opens
after
Forerunning
expires.
Second
Operation
0
Program
starts,
Pump
5
starts
20
(Interval)
20
seconds
later
Pump
3
starts
40
(Interval)
20
seconds
later
Pump
1
starts
(Relay
1
is
energised)
90
(Forerunning)
50
seconds
later
the
first
valve
opens
In
this
case
it
takes
90
seconds
before
the
first
valve
opens.
The
Relay
1
and
2
outputs
are
only
energised
after
Pump
1
and
2
has
been
started.
In
this
example
the
Relay
1
output
will
be
energised
after
40
seconds!
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...