User
Manual
Bed
‐
GK
1+2e
Rev.
03.04.2019
Page
49
/
143
Example
1:
Connection
of
Pressure
Sensor
with
Analogue
Output
A.
Suggested
pressure
sensor
Kobolt
Typ
3373.078.092
0
...
25bar
4
....
20ma
(Price:
ca.
.230.
‐
€)
B.
Wiring
schematic
Hints
and
tips:
After
the
connection
of
the
pressure
sensor,
it
will
be
best,
to
open
the
menu
„VCU
‐
Status“.
In
the
column
on
the
left
side
of
the
menu
you
will
find
the
current
values
for
the
analogue
inputs
1
to
4.
When
the
sensor
is
connected
according
the
above
sketch,
the
measured
current
value
is
shown
under
“Analogue
2”.
If
there
is
no
pressure
applied
to
the
pressure
sensor,
the
correct
reading
is:
4ma
If
there
is
no
reading,
please
check
whether
the
polarity
of
the
wiring
is
exchanged.
Please
check
furthermore,
whether
a
change
of
pressure
will
lead
to
a
change
of
the
readings.
If
yes,
the
sensor
is
wired
in
the
right
way.
C.
Readings
The
specified
range
of
the
pressure
sensor
is
0
–
25
bar
and
are
linear
covered
by
the
current
value
of
4
–
20
ma.
Содержание Greenkeeper Feedback
Страница 13: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 13 143 Left mouse click at System and device manager...
Страница 54: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 54 143 7 9 Wiring Schematic for VCU...
Страница 123: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 123 143 VCU...
Страница 134: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 134 143 15 1 5 FB Decoder Indication Light...
Страница 136: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 136 143...
Страница 141: ...User Manual Bed GK 1 2e Rev 03 04 2019 Page 141 143...