E-5
Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
890SD – Manufacturing Product Code
890SD -
-
-
Example:
890SD - 23 1300 B 0 - 0 37 - 1 A 0 0 0
Family
890 Standalone Drive
890SD
Induction Motor 230v ratings
Supply
kW
Output Current
(Vector Mode)
HP
Output Current
(Servo Mode)
Notes
Frame Size
Rating Data
230v 3ph
23
0.55
3.0
0.75
B
1300 B
1.1
5.5
1.5
B
1550 B
1.5
7.0
2.0
B
1700 B
2.2
11.0
3.0
B
2110 B
4.0
16.5
5.0
B
2165 B
5.5
24.0
7.5
C
2240 C
7.5
30.0
10
C
2300 C
Induction Motor 400v ratings
Induction Motor 460v ratings
Supply
kW
Output Current
(Vector Mode)
HP
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes
Frame Size
400/460v 3ph
43
37
73
50
73
E
2730 E
45
87
60
87
E
2870 E
55
105
75
100
F
3105 F
75
145
100
130
F
3145 F
90
180
125
156
F
3156 F
90
180
150
180
F
3180 F
110
216
175
216
G
3216 G
132
250
200
250
G
3250 G
160
316
250
316
G
3316 G
180
361
300
361
G
3361 G
200
375
375
H
3375 H
220
420
350
420
H
3420 H
250
480
400
480
H
3480 H
280
520
450
520
H
3520 H
315
590
500
590
J
3590 J
Induction Motor 400v ratings
Induction Motor 460v ratings
Supply
kW
Output Current
(Vector Mode)
HP
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes
Frame Size
400/500v 3ph
53
0.55
2.0
0.75
2.0
B
1200 B
1.1
3.5
1.5
3.5
B
1350 B
1.5
4.5
2.0
4.5
B
1450 B
2.2
6.0
3.0
5.0
B
1600 B
4.0
10.0
5.0
8.0
B
2100 B
5.5
12.0
7.5
12.0
B
2120 B
7.5
16.0
10.0
14.0
B
2160 B
7.5
16.0
10.0
14.0
30% more peak
B
216S B
11.0
24.0
15.0
24.0
C
2240 C
15.0
30.0
20.0
30.0
C
2300 C
15.0
30.0
20.0
30.0
30% more peak
C
230S C
18.5
39.0
25.0
35.0
D
2390 D
22.0
45.0
30.0
40.0
D
2450 D
30.0
59.0
40.0
52.0
D
2590 D
Induction Motor 400v/500v ratings
Supply
kW
Output Current
(Vector Mode)
Output Current
(Vector Mode)
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes
Frame Size
400/500v 3ph
53
37
67
E
2730 E
45
79
E
2870 E
55
100
F
3105 F
75
125
F
3145 F
90
156
F
3156 F
Auxiliary supply
Not required (frames B-E)
0
115v 1ph (Frame F-J only)
1
230v 1ph (Frame F-J only)
2
Brake Switch
Not Fitted (optional Frame G-J only)
0
B
rake switch fitted (mandatory Frame B-F, optional Frame G-J)
B
Special Option
None
00
Active Front End ('Y' caps removed - Frames E to J only)
07
Documented special options (01-99)
Performance Level
Advanced
1
High
2
Destination
English (50Hz)
A
English (60Hz)
B
Option F
None
0
SinCos Encoder (Endat 2.1)
1
Incr. Quadr. Encoder
3
Resolver
5
Resolver Repeater
6
Mark Registration (Endat 2.1 Encoder) - with restricted functionality
7
Line Synchronisation
L
Option A
Not fitted
0
Ca
n
Open Comms
N
C
ontrolNet Comms
C
D
eviceNet
D
Et
h
erNet /IP
H
Modbus
T
CP/IP
T
P
rofibus Comms
P
Mark Registration (Endat 2.1 Encoder) with restricted functionality
7
RS485
S
EtherCAT
K
Analogue Input Option (if fitted in slot A cannot be fitted in slot B)
R
Encoder Option (if fitted in slot A cannot be fitted in slot B)
E
Option B
Not fitted
0
Firewire 1394
A
A
Special peer-peer protocol (may only be fitted when CanOpen or DeviceNet option is not fitted in slot A)
X
Analogue Input Option (if fitted in slot B cannot be fitted in slot A)
R
Encoder Option (if fitted in slot B cannot be fitted in slot A)
E