D-236
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
111.06 ACTIVE
PHASE TUNING
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
111.08 REFERENCE TYPE PHASE TUNING
ENUM
0 : SQUARE
1 : SINUSOIDAL
2 : TRIANGULAR
SQUARE
rw
111.09 SPEED AMPLITUDE PHASE TUNING
REAL
0.0000 to 100.0000 rev/s 0.1000 rev/s
rw
111.12 RUN TR FUNC
TEST
PHASE TUNING
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
111.13 NO OF
MEASRMENTS
PHASE TUNING
INT
1 to 10000
100
rw
111.14 TORQUE
AMPLITUDE
PHASE TUNING
REAL
0.00 to 100.00 %
20.00 %
rw
111.15 TRANSF FUNC
TYPE
PHASE TUNING
ENUM
0 : SPEED TRANSFR
FN
1 : OPEN LP TRANS FN
2 : CURRENT LP TR FN
OPEN LP TRANS FN
rw
111.16 POSN AMPLITUDE PHASE TUNING
REAL
0.0000 to 100.0000 deg
1.0000 deg
rw
111.17 MEASURMENTS
DONE
PHASE TUNING
INT
_
0
ro
Output
112.01 ENABLE
POWER LOSS
CNTRL
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
112.02 TRIP THRESHOLD
POWER LOSS
CNTRL
REAL
0 to 1000 V
447 V
rw
3,5
112.03 CONTROL BAND
POWER LOSS
CNTRL
REAL
0 to 1000 V
20 V
rw
112.04 ACCEL TIME
POWER LOSS
CNTRL
REAL
0.01 to 300.00 s
10.00 s
rw
112.05 DECEL TIME
POWER LOSS
CNTRL
REAL
0.01 to 300.00 s
5.00 s
rw