10-27
Keypad Menus
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
QUICK SETUP MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6901 Display
Description
Range
Default
80.02
AUTOTUNE MODE
Selects the Autotune operating mode.
0 : STATIONARY
1 : ROTATING
2 : SPD LOOP
ROTATING
3 : SPD LOOP
STATIONARY
27.06
(induction
motor
only)
MAG CURRENT
This parameter contains the motor model no-
load line current as determined by the
Autotune, or taken from the motor nameplate
0.00 to 3276.70 A product code
dependent
27.14
(induction
motor
only)
STATOR RES
This parameter contains the motor model per-
phase stator resistance as determined by
Autotune.
0.0000 to
250.0000
Ω
product code
dependent
27.15
(induction
motor
only)
LEAKAGE INDUC This parameter contains the motor model per-
phase leakage inductance as determined by
Autotune.
0.00 to 300.00mH product code
dependent
27.16
(induction
motor
only)
MUTUAL INDUC
This parameter contains the motor model per-
phase mutual inductance as determined by
Autotune.
0.00 to 3000.00mH product code
dependent