Programming
D-195
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
21.27 USER VOLTAGE 9
FLUXING
REAL
0.0 to 100.0 %
90.0 %
rw
21.28 USER FREQ 10
FLUXING
REAL
0.0 to 100.0 %
100.0 %
rw
21.29 USER VOLTAGE 10 FLUXING
REAL
0.0 to 100.0 %
100.0 %
rw
22.01 ENABLE
SLEW RATE LIMIT BOOL
0 : FALSE
1 : TRUE
TRUE
rw
22.02 ACCEL LIMIT
SLEW RATE LIMIT REAL
1.0 to 1200.0 Hz/s
500.0 Hz/s
rw
22.03 DECEL LIMIT
SLEW RATE LIMIT REAL
1.0 to 1200.0 Hz/s
500.0 Hz/s
rw
23.01 ENABLE
SLIP COMP
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
2
23.02 MOTORING LIMIT
SLIP COMP
REAL
0.0 to 600.0 RPM
150.0 RPM
rw
5
23.03 REGEN LIMIT
SLIP COMP
REAL
0.0 to 600.0 RPM
150.0 RPM
rw
5
25.01 ENABLE
STABILISATION
BOOL
0 : FALSE
1 : TRUE
TRUE
rw
27.02 POWER
MOTOR
INDUCTION
REAL
0.00 to 3000.00 kW
30.00 kW
rw
3
27.03 BASE FREQUENCY MOTOR
INDUCTION
REAL
7.5 to 1000.0 Hz
50.0 Hz
rw
2,4
27.04 MOTOR VOLTAGE
MOTOR
INDUCTION
REAL
0.0 to 690.0 V
400.0 V
rw
3,4
27.05 MOTOR CURRENT MOTOR
INDUCTION
REAL
0.00 to 3276.70 A
54.00 A
rw
2,3
27.06 MAG CURRENT
MOTOR
INDUCTION
REAL
0.00 to 3276.70 A
16.20 A
rw
3
27.07 NAMEPLATE RPM
MOTOR
INDUCTION
REAL
0.0 to 30000.0 RPM
1470.0 RPM
rw
3,4
27.08 MOTOR
CONNECTION
MOTOR
INDUCTION
ENUM
0 : DELTA
1 : STAR
STAR
rw
3,4