D-194
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
19.01 VALUE
DIGITAL OUTPUT
3
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
1
21.01 V/F SHAPE
FLUXING
ENUM
0 : LINEAR LAW
1 : FAN LAW
2 : USER DEFINED
LINEAR LAW
rw
21.03 FIXED BOOST
FLUXING
REAL
0.00 to 25.00 %
0.00 %
rw
3
21.04 AUTO BOOST
FLUXING
REAL
0.00 to 25.00 %
0.00 %
rw
21.08 ACCELRTN BOOST FLUXING
REAL
0.00 to 25.00 %
0.00 %
rw
21.09 ENERGY SAVING
FLUXING
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
21.10 USER FREQ 1
FLUXING
REAL
0.0 to 100.0 %
10.0 %
rw
21.11 USER VOLTAGE 1
FLUXING
REAL
0.0 to 100.0 %
10.0 %
rw
21.12 USER FREQ 2
FLUXING
REAL
0.0 to 100.0 %
20.0 %
rw
21.13 USER VOLTAGE 2
FLUXING
REAL
0.0 to 100.0 %
20.0 %
rw
21.14 USER FREQ 3
FLUXING
REAL
0.0 to 100.0 %
30.0 %
rw
21.15 USER VOLTAGE 3
FLUXING
REAL
0.0 to 100.0 %
30.0 %
rw
21.16 USER FREQ 4
FLUXING
REAL
0.0 to 100.0 %
40.0 %
rw
21.17 USER VOLTAGE 4
FLUXING
REAL
0.0 to 100.0 %
40.0 %
rw
21.18 USER FREQ 5
FLUXING
REAL
0.0 to 100.0 %
50.0 %
rw
21.19 USER VOLTAGE 5
FLUXING
REAL
0.0 to 100.0 %
50.0 %
rw
21.20 USER FREQ 6
FLUXING
REAL
0.0 to 100.0 %
60.0 %
rw
21.21 USER VOLTAGE 6
FLUXING
REAL
0.0 to 100.0 %
60.0 %
rw
21.22 USER FREQ 7
FLUXING
REAL
0.0 to 100.0 %
70.0 %
rw
21.23 USER VOLTAGE 7
FLUXING
REAL
0.0 to 100.0 %
70.0 %
rw
21.24 USER FREQ 8
FLUXING
REAL
0.0 to 100.0 %
80.0 %
rw
21.25 USER VOLTAGE 8
FLUXING
REAL
0.0 to 100.0 %
80.0 %
rw
21.26 USER FREQ 9
FLUXING
REAL
0.0 to 100.0 %
90.0 %
rw