D-232
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
99.05 1SEC OVER
RATING
DYNAMIC
BRAKING
REAL
1 to 40
25
rw
2,3
99.06 BRAKING
DYNAMIC
BRAKING
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
99.07 INT DB RESISTOR
DYNAMIC
BRAKING
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
3
100.01 RAMP TYPE
REFERENCE
RAMP
ENUM
0 : LINEAR
1 : S
LINEAR
rw
100.02 ACCEL TIME
REFERENCE
RAMP
REAL
0.0 to 3000.0 s
20.0 s
rw
3
100.03 DECEL TIME
REFERENCE
RAMP
REAL
0.0 to 3000.0 s
20.0 s
rw
3
100.04 SYMMETRIC MODE REFERENCE
RAMP
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
100.05 SYMMETRIC TIME
REFERENCE
RAMP
REAL
0.0 to 3000.0 s
20.0 s
rw
3
100.06 SRAMP
CONTINUOUS
REFERENCE
RAMP
BOOL
0 : FALSE
1 : TRUE
TRUE
rw
100.07 SRAMP ACCEL
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^2
10.00 /s^2
rw
100.08 SRAMP DECEL
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^2
10.00 /s^2
rw
100.09 SRAMP JERK 1
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^3
10.00 /s^3
rw
100.10 SRAMP JERK 2
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^3
10.00 /s^3
rw
100.11 SRAMP JERK 3
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^3
10.00 /s^3
rw
100.12 SRAMP JERK 4
REFERENCE
RAMP
REAL
0.00 to 100.00 /s^3
10.00 /s^3
rw