Programming
D-45
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Parameter Descriptions
SPEED FBK RPM
PREF: 70.04
Default: —.xx rpm
Range: —.xx rpm
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
•
In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per minute as
calculated from the speed feedback device.
•
In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
minute.
•
In VOLTS/Hz mode the parameter shows motor synchronous speed in rpm.
•
In PMAC control mode, the parameter shows the mechanical speed of the motor shaft.
SPEED FBK REV/S
PREF: 70.05
Default: —.xx rev/s
Range: —.xx rev/s
This parameter changes according to the CONTROL MODE (DRIVE CONFIG function block):
•
In CLOSED-LOOP VEC mode the parameter shows the mechanical speed of the motor shaft in revolutions per second as
calculated from the motor speed feedback.
•
In SENSORLESS VEC mode the parameter shows the calculated mechanical speed of the motor shaft in revolutions per
second.
•
In VOLTS / Hz mode, the parameter shows the motor synchronous speed in revolutions per second.
•