background image

BitStorm

 4800

User’s Guide

Document No. 4800-A2-GB20-10

July 2002

Содержание BitStorm 4800 Express

Страница 1: ...BitStorm 4800 User s Guide Document No 4800 A2 GB20 10 July 2002...

Страница 2: ...epresentative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worl...

Страница 3: ...inology and Conventions System Terminology 2 1 Port 2 1 Unit 2 1 Stack 2 1 DSL Port ID 2 2 Ethernet Port ID 2 3 Reserved Names 2 3 3 Using the Command Line Interface Overview 3 1 Access Levels 3 1 Log...

Страница 4: ...5 1 System Log 5 2 Viewing the System Log 5 2 Message Format 5 2 Messages 5 3 Front Panel LEDs 5 6 Show Commands and Web Interface Status Screens 5 6 A CLI Command Descriptions CLI Commands A 1 Back...

Страница 5: ...figure User Accounts A 46 Copy A 47 End A 47 Exit A 48 Firmware A 48 Paging A 49 Password A 50 Privilege A 50 Restart A 51 Save A 51 Show A 52 Test A 72 B SNMP Traps C MIB Support Overview C 1 Locatin...

Страница 6: ...aceTCTable C 28 atmVclTable C 28 ATM FORUM SNMP M4 MIB C 29 RS 232 MIB C 30 rs232Number C 30 rs232PortTable C 31 rs232AsyncPortTable C 31 rs232SyncPortTable C 32 Ethernet Like MIB C 33 dot3StatsTable...

Страница 7: ...le C 47 PDN MPE DEVICE CONTROL MIB C 48 PDN MPE DSLAM SYSTEM MIB C 48 PDN MPE HEALTH AND STATUS MIB C 48 PDN MPE ENTITY SENSOR MIB C 48 PDN ARP MIB C 49 pdnNetToMediaConfig Group C 49 ipNetToMediaConf...

Страница 8: ...PDN INET CONFIG MIB C 58 pdnInetIpAddressTable Group C 58 PDN SYSLOG MIB C 59 PDN UPLINK TAGGING MIB C 59 PDN STACKABLE MIB C 59 PDN DEVICE TIME MIB C 59 D OID Cross Reference OID Numbers D 1 E CLI to...

Страница 9: ...the capabilities of the BitStorm 4800 Chapter 2 Terminology and Conventions Defines terms used in this manual and in the product s user interfaces Chapter 3 Using the Command Line Interface Explains...

Страница 10: ...Reference Contains a table showing what MIB objects are used to implement CLI commands Appendix F Reference Tables Contains tables used in CLI commands and web interface screens Index Lists key terms...

Страница 11: ...F draft ietf adslmib adslext 07 txt Definitions of Extention Managed Objects for ADSL Lines ITU T 992 1 Single Pair High Speed Digital Subscriber Line SHDSL transceivers ITU T 992 2 Asymmetrical digit...

Страница 12: ...About This Guide x July 2002 4800 A2 GB20 10...

Страница 13: ...olutions with switches routers and servers that require rewiring buildings and expensive downsized ATM DSLAMs not designed for Multi Tenant Unit MTU Multi Dwelling Unit MDU applications Figure 1 1 Bit...

Страница 14: ...m 4800 Figure 1 2 BitStorm 4800 Sample Application Splitter ASDL CPE Phone Filter Service Management System Voice Gateway Class Switch BitStorm 4800 Optional Adjunct Server or Service Gateway Building...

Страница 15: ...for maximum performance and minimum packet loss Auto rating DSL technology to adjust to line conditions Auto sensing on all Ethernet ports to adjust automatically to the speed of attached devices Auto...

Страница 16: ...1 BitStorm 4800 Overview 1 4 July 2002 4800 A2 GB20 10...

Страница 17: ...a BitStorm 4800 or Management Module These are ALARM CONSOLE DOWNLINK GigE RJ45 DOWNLINK GigE SFP DSL Ports 1 24 24 port model or 1 48 48 port model MGMT MODEM UPLINK GigE RJ45 UPLINK GigE SFP V 35 X...

Страница 18: ...ort Number The port ID can be expressed as a combination of the BitStorm 4800 unit number and a port number In the initial release 1 is the only valid unit number Example IAC configure interface dsl 1...

Страница 19: ...n combination with the unit number to identify the three ports Unit number is described in System Terminology on page 2 1 The term Port ID in this manual in reference to an Ethernet port refers to any...

Страница 20: ...2 Terminology and Conventions 2 4 July 2002 4800 A2 GB20 10...

Страница 21: ...sions Access Levels CLI users have one of two access levels User The user may display certain configuration and status information Administrator The user has access to all commands The Administrator l...

Страница 22: ...time you log in just press Enter The following prompt is displayed IAC For security purposes immediately establish new passwords for the user name admin See Configure User Accounts in Appendix A CLI...

Страница 23: ...g the back command Back Command The back command positions the CLI up one level in the command tree For example if DSL interface 1 1 is being configured the following prompt is displayed IAC configure...

Страница 24: ...yed on line 24 of your screen and you can do the following To view the next screen of output press the spacebar To view the next line of output press the Enter key To return to the command line press...

Страница 25: ...exit a command line prompt without answering or abort the command in progress Ctrl z Terminate a privileged mode session and continue the session in standard mode If Ctrl z is entered by a user not in...

Страница 26: ...You must enter the save command to save your changes to the startup configuration in NVRAM Non Volatile RAM If there are unsaved changes an exclamation point is added to the prompt to remind you or ot...

Страница 27: ...status Perform diagnostics Web interface users have one of two access levels User The user may display certain configuration and status information Administrator The user has access to all screens an...

Страница 28: ...nterface can be reached by clicking on hyperlinks in the four menu boxes on the left side of the screen Status Use the Status screens to display statistics status and contents of memory The Status scr...

Страница 29: ...uration Use the Configuration screens to configure the system interfaces and filters System Use the System screens to display system information download firmware back up configurations and modify use...

Страница 30: ...security use the System Users screen to immediately change the default password for the admin user Configuring the System Use the Configuration screens to configure the following Bridge table Filters...

Страница 31: ...n Procedure To save your configuration to non volatile RAM 1 Go to the System Save and Restore screen 2 Click on Save Running Config Logging Out To end a session close your Web browser This prevents a...

Страница 32: ...4 Using the Web Interface 4 6 July 2002 4800 A2 GB20 10...

Страница 33: ...Troubleshooting Overview The chapter describes ways to monitor the status of the BitStorm 4800 and to diagnose problems These include System Log on page 5 2 Front Panel LEDs on page 5 6 Show Commands...

Страница 34: ...e level of messages written to the log can be set using configure syslog command of the Command Line Interface or the Configuration Syslog screen of the Web interface The levels are emergency Only eme...

Страница 35: ...Configured Mgmt IP Address Address Address address Mask mask Gateway address Alert An administrator has replaced the management IP address and gateway address obtained by BOOTP Cold Start Completed Sy...

Страница 36: ...replaced by Bootp Obtained Mgmt IP Address Address Address address Mask mask Gateway address Alert The manually set management IP address and gateway address have been replaced by those obtained from...

Страница 37: ...t Agent POST results from subsystem Failed Alert The Power On Self Test of the specified subsystem failed Notify your service representative Time Client unable to locate NTP Server Alert The SNTP serv...

Страница 38: ...tion For Information About Use the CLI Command Use the Web Interface Screen Bridge show bridge Status Bridge Filters show filter Configuration Filter Filter Bindings show filter binding Configuration...

Страница 39: ...ce of optional parameters Command parameters enclosed in neither brackets nor braces are required A choice of required parameters Command parameters enclosed in neither brackets nor braces are require...

Страница 40: ...vel User The back command positions access up one level in the command tree For example if DSL interface 1 1 is being configured the following prompt is displayed IAC configure interface dsl 1 1 The b...

Страница 41: ...ess_8 Specifies one or more NMS addresses Example IAC clear management snmp nms address 137 70 92 192 clear management snmp nms traps ip_address_1 ip_address_8 Minimum Access Level Administrator The c...

Страница 42: ...ble A 3 Configure Command configure Minimum Access Level Administrator The configure command causes the CLI to enter configuration mode Once the IAC configure prompt is displayed you can enter one of...

Страница 43: ...rivate network connected to the uplink and never forwards data on another DSL port In addition a management Virtual Local Area Network VLAN is created on the uplink for use by the SMS switch Switched...

Страница 44: ...is month day and year hh mm Specifies the time in hours 0 23 and minutes 0 59 Example IAC configure date 03 21 02 13 05 configure date timezone time_zone Minimum Access Level Administrator The configu...

Страница 45: ...ccess Memory NVRAM Factory defaults include a management address of 10 10 10 10 so if you are managing the BitStorm 4800 using Telnet over a different address your connection is terminated upon execut...

Страница 46: ...filter to be created The name may contain up to 32 printable characters forward Specifies that a packet is to be forwarded to the user when none of the conditions specified in the rule or rules are ma...

Страница 47: ...and from the port is affected by the filter port_id Specifies the DSL port whose traffic is to be filtered Example IAC configure filter binding create no_at_or_ipx 1 1 configure filter binding delete...

Страница 48: ...her Specifies that the rule applies to Layer 2 Ethernet traffic ether snap Specifies that the rule applies to Layer 2 SubNetwork Access Protocol SNAP traffic ethertypes Specifies the Ethertype the rul...

Страница 49: ...inistrator The configure interface console parity command sets the parity bit type for the Console port parity Valid choices are none odd and even The default is none Example IAC configure interface c...

Страница 50: ...nection Valid input is the VPI VCI for the data connection The default is 0 35 The valid range for VPI is 0 15 The valid range for VCI is 32 255 Examples IAC configure interface dsl 1 1 atm data conne...

Страница 51: ...interleave buffer is used port_id Identifies the port to be configured The possible forms of the identifier are described in System Terminology in Chapter 2 Terminology and Conventions latency Valid c...

Страница 52: ...t toward the CPE If behavior is set to fixed this is the only downstream rate port_id Identifies the port to be configured The possible forms of the identifier are described in System Terminology in C...

Страница 53: ...nology in Chapter 2 Terminology and Conventions margin Valid choices are 0 15 dB in 1 dB increments The default is 0 Examples IAC configure interface dsl 1 1 min snr margin 9 configure interface dsl p...

Страница 54: ...margin Minimum Access Level Administrator The configure interface dsl target downstream margin command specifies the Signal to Noise Ratio SNR margin in dB required at startup for traffic from the por...

Страница 55: ...l enabled disabled Minimum Access Level Administrator The configure interface ethernet flow control command specifies whether flow control should be used on the port port_id Identifies the Ethernet po...

Страница 56: ...m Access Level Administrator The configure interface ethernet show command displays parameters for an Ethernet port without leaving configuration mode port_id Identifies the port whose configuration i...

Страница 57: ...200 2400 4800 9600 19200 38400 57600 115200 Minimum Access Level Administrator The configure interface modem rate command sets the rate of the Modem port in bps rate Valid rates are 1200 2400 4800 960...

Страница 58: ...is is the default Example IAC configure interface v35 flow control dsr configure interface v35 idle char flag mark Minimum Access Level Administrator The configure interface v35 idle char command spec...

Страница 59: ...n mode Example IAC configure interface v35 show configure interface v35 state disabled enabled Minimum Access Level Administrator The configure interface v35 state command specifies the availability o...

Страница 60: ...in settings determine the highest rates the modems can train to These rates may be less than the maximum configured rates For example if target downstream margin is set to 6 the modems will train esta...

Страница 61: ...y IP parameters Table A 11 Configure IP Command configure ip nhr ip_address Minimum Access Level Administrator The configure ip nhr command determines the Next Hop Router NHR address for all ports in...

Страница 62: ...the management IP address The default address is 10 10 10 10 subnet_mask Specifies the subnet mask to be applied to the IP address The default mask is 255 255 255 0 default_gateway Specifies the mana...

Страница 63: ...h alg sha1 md5 Minimum Access Level Administrator The configure management ipsec connection default ah alg command sets the default Authentication Header protocol algorithm sha1 Specifies that the def...

Страница 64: ...string of up to 16 hexadecimal digits 0 f The default is 21aaaaaaaaaaaaaa Example IAC configure management ipsec connection default des key d2e4d3c1 configure management ipsec connection default encry...

Страница 65: ...s the default key This is a string of up to 40 hexadecimal digits 0 f The default is 21aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Example IAC configure management ipsec connection default esp sha1 key d2e...

Страница 66: ...connection modify antireplay command determines whether the anti replay feature is used connection_name Specifies the name of the connection policy to modify disable Specifies that anti replay is not...

Страница 67: ...nection policy to modify ah Specifies that the protocol is Authentication Header esp Specifies that the protocol is Encapsulating Security Payload Example IAC configure management ipsec connection mod...

Страница 68: ...gure management ipsec connection modify spi command sets the Security Profile Index for the Encapsulating Security Payload protocol for a specified connection connection_name Specifies the name of the...

Страница 69: ...m 4800 If SNMP Access Validation is disabled these addresses have no effect nms_address1 nms_address8 Specifies one to eight IP addresses of NMS workstations Example IAC configure management snmp nms...

Страница 70: ...ate disabled enabled Minimum Access Level Administrator The configure management snmp state command specifies the availability of the SNMP agent state Valid choices are disabled and enabled The defaul...

Страница 71: ...t automatic configuration backup will occur after each configuration change hh mm Specifies the amount of time after a configuration change that a configuration backup will automatically occur Time is...

Страница 72: ...associated with the user name filename Specifies the file containing the configuration backup Example IAC configure scheduler ftp 135 27 90 98 admin admnpass iac2_bkup configure scheduler ftp timesta...

Страница 73: ...t be in multiplex forwarding mux mode else the following message is displayed Command not allowed System must be in mux forwarding mode See Table A 4 Configure Bridge Command for information about mux...

Страница 74: ...ss Level Administrator The configure security ip max ip command specifes the number of IP addresses allowed to be active on a particular DSL port For more information see IP Security on page A 38 port...

Страница 75: ...letes a MAC address in the table of addresses allowed to send data to a particular DSL port port_id Identifies the port to be affected The possible forms of the identifier are described in Chapter 2 T...

Страница 76: ...ot be able to obtain MAC information for this subscriber s host A host that is connected on the DSL side of the unit cannot obtain MAC address information about any host other than the port s Next Hop...

Страница 77: ...SNTP requests Date and time must be set manually enable The unit updates the date and time periodically by sending requests to an SNTP server Example IAC configure sntp disable configure sntp address...

Страница 78: ...ages are written to the system log only if they are received more than five minutes apart Example IAC configure syslog rate limiting disabled configure syslog threshold emergency alert information deb...

Страница 79: ...igure system information system location command stores the location of the system location Up to 36 printable characters No spaces are allowed Example IAC configure system information system location...

Страница 80: ...ons inactivity timeout command specifies how long a telnet session can exist with no activity before it is terminated by the system time Specifies the amount of time in minutes an inactive telnet sess...

Страница 81: ...tem options test timeout command specifies the maximum amount of time a disruptive test is allowed to run time Specifies the amount of time in minutes a disruptive test can run before it is terminated...

Страница 82: ...port is the default uplink This command therefore allows you to override the default by specifying the GigE Uplink port as the uplink Table A 19 Configure Uplink Command configure uplink gige uplink...

Страница 83: ...3263 3264 3311 3584 3584 3631 3632 3679 3680 3727 3728 3775 3776 3823 Table A 21 Configure Uplink Tag Command configure uplink tag base base Minimum Access Level Administrator The configure uplink ta...

Страница 84: ...d modifies the password or passwords for the user login_password Specifies a password of 1 15 printable characters Spaces are not allowed A login password is required of all users privilege_password S...

Страница 85: ...ame A user name allowed on the FTP server password The password associated with the user name filename The name of the source or destination file running config Specifies that the source or destinatio...

Страница 86: ...rmware download command downloads new firmware to the BitStorm 4800 and optionally applies it immediately ip_address Specifies the network address of the FTP server user_name Specifies a user name acc...

Страница 87: ...itch IAC Switch from firmware revision S01 02 03 to firmware revision S01 02 04 yes no yes IAC Firmware switched system rebooting Table A 26 Firmware Command 2 of 2 Table A 27 Paging Command paging di...

Страница 88: ...le A 28 Password Command password Minimum Access Level User The password command changes the user or administrator privilege password depending on which level is active Example IAC password enter old...

Страница 89: ...unit command restarts the unit causing it to reload the startup configuration and retrain the DSL ports Example IAC restart unit 1 Table A 31 Save Command save Minimum Access Level Administrator The s...

Страница 90: ...m treats each DSL port as if it were a private network connected to the uplink and never forwards data on another DSL port In addition a management VLAN is created on the uplink for use by the SMS Tot...

Страница 91: ...single filter Example IAC show filter Display results filter name The name of the filter action The action to be performed forward Specifies that a packet is to be forwarded to the user when none of t...

Страница 92: ...filter direction The direction of the data stream affected by this binding inbound Traffic toward the port is affected outbound Traffic from the port is affected show filter rule rule_name Minimum Ac...

Страница 93: ...d all statistics are cleared clear statistics Resets to zero the statistics for this session This affects only the statistics displayed using the show command during this session All statistics contin...

Страница 94: ...ink s status cannot be determined up The link is enabled and ready to send packets Line Rate Up The upstream data rate Line Rate Down The downstream data rate Margin Up The amount of distortion that c...

Страница 95: ...SL port port_id Specifies that the display should be limited to this specified port If all is specified information is displayed for all ports statistics Specifes that the error statistics for the spe...

Страница 96: ...lls from the CPE whose headers were corrected total OCD Number of Out of Cell Delineation events on the link from the CPE Ethernet Statistics total frames discarded Number of frames discarded due to e...

Страница 97: ...ethernet statistics command displays statistics for all Ethernet ports or a specified port port_id Specifies that the display should be limited to this specified port If all is specified information...

Страница 98: ...4804 Management Module clear statistics Resets to zero the statistics for this session This affects only the statistics displayed using the show command during this session All statistics continue to...

Страница 99: ...electrical interface eia530a The interface is EIA 530 A v35 The interface is V 35 x21 The interface is X 21 RTS The status of the Request To Send lead on or off CTS The status of the Clear To Send le...

Страница 100: ...IAC show management arp Display results ip address The IP address of the entry mac address The hardware address of the entry type The source of the address dynamic The address was learned static The a...

Страница 101: ...inimum Access Level User The show management vlan command displays the settings for Bridge Mode and management VLAN tagging Example IAC show management vlan Display results Bridge Mode The Bridge Mode...

Страница 102: ...port ID IP Address IP address allowed on the port NHR Next Hop Router for the port Type The source of the address dynamic The address was learned static The address was added to the table of allowed a...

Страница 103: ...log command displays the configuration and contents of the system log Example IAC show syslog Display results threshold The level of messages written to the log emergency Only emergency messages are w...

Страница 104: ...of days hours minutes and seconds the unit has been running Model The Paradyne model number of Unit n Serial Number The unit serial number Main Card HW Rev The hardware revision level of the main circ...

Страница 105: ...of time a test is allowed to run port number display format The format of port IDs used in system messages name Port name SLE Single Logical Entity number unit port Unit number and port number date d...

Страница 106: ...clock p for pass or f for fail SDRAM Synchronous Dynamic Random Access Memory p for pass or f for fail DSL ports results displayed for ports 1 24 or 1 48 p for pass or f for fail Memory Port SDRAM Da...

Страница 107: ...port numbers 1 24 or 1 48 is one of the following D Port is down U Port is up period Port is disabled show technical support Minimum Access Level User The show technical support command shows contact...

Страница 108: ...ccounts command shows user names configured in the system Example IAC show user accounts Display results User Name The name used for logging in Passwords are not displayed Privilege Level The access l...

Страница 109: ...d VLAN tag number vlan_tag Specify a valid VLAN tag number for this unit 16 3823 or the keyword all to display all MAC addresses for all ports Examples IAC show vlans 63 IAC show vlans all Display res...

Страница 110: ...35 X 21 port to normal mode terminating the test If the command is not issued to stop the test the test stops automatically after the number of minutes specified in the test timeout value of the confi...

Страница 111: ...apEnterprise devAuthenticationFailure IpAddress SNMPv2 MIB coldStart External power cycle of the device has occurred hardware reset Warning snmpTrapOID snmpTrapEnterprise SNMPv2 MIB devFileXferEvent A...

Страница 112: ...emperature condition cleared Major entPhysicalIndex mpeEntSensorThresholdValue mpeEntSensorValue MPE ENTITY SENSOR MIB mpeEntSensorSystem ResetNotification System shut down due to over temperature con...

Страница 113: ...age C 7 PDN HEADER MIB on page C 7 IP MIB on page C 8 ENTITY MIB on page C 9 IF MIB on page C 13 ATM MIB on page C 27 ATM FORUM SNMP M4 MIB on page C 29 RS 232 MIB on page C 30 Ethernet Like MIB on pa...

Страница 114: ...N FILTER MIB on page C 57 PDN INET CONFIG MIB on page C 58 PDN SYSLOG MIB on page C 59 PDN UPLINK TAGGING MIB on page C 59 PDN STACKABLE MIB on page C 59 PDN DEVICE TIME MIB on page C 59 Locating MIBs...

Страница 115: ...1213 MIB RFC 1213 Yes IANAifType MIB http www iana org assignments ianaiftype mib PDN HEADER MIB pdn_Header mib See PDN HEADER MIB on page C 7 PDN TC pdn_tc mib SNMP FRAMEWORK MIB RFC 2571 IP MIB RFC...

Страница 116: ...es PDN CONTROL MIB pdn_Control mib Yes PDN IPSEC MANUAL MIB pdn_IPSec mib Yes PDN IF EXT MIB pdn_IfExt mib Yes PDN SECURITY MIB pdn_Security mib Yes PDN SYNCPORTSTATS MIB pdn_SyncPortStats mib Yes PDN...

Страница 117: ...y yy yy Where yy yy yy Is the software revision number Table C 2 System Group OIDs Object OID Syntax Access Status Supported sysDescr system 1 DisplayString read only current Yes sysObjectID system 2...

Страница 118: ...ad only current Yes snmpInASNParseErrs snmp 6 Counter32 read only current Yes snmpInTooBigs snmp 8 Counter read only obsolete No snmpInNoSuchNames snmp 9 Counter read only obsolete No snmpInBadValues...

Страница 119: ...ses snmp 28 Counter read only obsolete No snmpOutTraps snmp 29 Counter read only obsolete No snnpEnableAuthenTraps snmp 30 INTEGER read write current Yes snmpSilentDrops snmp 31 Counter32 read only cu...

Страница 120: ...5 Counter32 read only current No ipForwDatagrams ip 6 Counter32 read only current No ipInUnknownProtos ip 7 Counter32 read only current No ipInDiscards ip 8 Counter32 read only current No ipInDeliver...

Страница 121: ...ible current Yes entLogicalTable entityLogical 1 Sequence of entLogical Entry not accessible current No entLPMappingTable entityMapping 1 Sequence of entLPMapping Entry not accessible current No entAl...

Страница 122: ...C 7 entPhysicalIndex Values 1 of 2 Entity Physical Index RR CC SS L PPP Stack 00 00 00 0 001 Chassis 00 cc 00 0 000 Main Card 00 cc 00 0 001 Child Card 00 cc 00 0 002 Management Module 00 cc 00 0 003...

Страница 123: ...00 cc 00 0 502 V 35 Processor PLD 00 cc 00 0 503 ADSL Port y 00 cc 00 1 yyy where yyy 1 48 for DSL ports 1 48 Ethernet Management Port 00 cc 00 1 060 Ethernet Downlink Port 00 cc 00 1 061 Ethernet Up...

Страница 124: ...anagement Processor PLD 1 3 6 1 4 1 1795 1 14 17 6 4 ips pld Model 4800 Management Module 1 3 6 1 4 1 1795 1 14 17 4 1 ips mgmt no wan Model 4804 Management Module 1 3 6 1 4 1 1795 1 14 17 4 2 ips mgm...

Страница 125: ...y not accessible current Yes ifXTable ifMIBObjects 1 Sequence of ifXEntry not accessible current Yes ifStackTable ifMIBObjects 2 Sequence of ifStackEntry not accessible current Yes ifTestTable ifMIBOb...

Страница 126: ...3 Uplink Port or Ethernet PPP Layer 2 Uplink Port V 35 EIA 530 A X 21 External 1 Port per Stack PPP Uplink HDLC Interface External 1 per Stack PPP Uplink PPP Interface External 1 per Stack PPP Uplink...

Страница 127: ...rent Yes ifLastChange ifEntry 9 TimerTicks read only current Yes ifInOctets ifEntry 10 Counter32 read only current Yes ifInUcastPkts ifEntry 11 Counter32 read only current Yes ifInNUcastPkts ifEntry 1...

Страница 128: ...0 50 External Modem Port 0 51 External Ethernet Management Port 1 60 External Ethernet Downlink Port 1 61 External Ethernet Uplink Port 1 62 External Ethernet PPP Layer 2 Uplink Port V 35 X 21 port 1...

Страница 129: ...External PPP Uplink HDLC Interface PPP Uplink HDLC Interface External PPP Uplink PPP Interface PPP Uplink PPP Interface Internal PPP Uplink Ethernet Interface PPP Ul En Interface Internal Layer 2 Swit...

Страница 130: ...Uplink Port v35 45 External PPP Uplink HDLC Interface hdlc 118 External PPP Uplink PPP Interface ppp 23 Internal PPP Uplink Ethernet Interface ethernetCsmacd 6 Internal Layer 2 Switch PPP Uplink Proce...

Страница 131: ...k Port 1500 External Ethernet Uplink Port 1500 External IP PPP Layer 3 Uplink Port or Ethernet PPP Layer 2 Uplink Port 1504 External PPP Uplink HDLC Interface 1504 External PPP Uplink PPP Interface 15...

Страница 132: ...up 1 or down 2 External Ethernet PPP Layer 2 Uplink Port Only valid values are up 1 or testing 3 External PPP Uplink HDLC Interface Only valid value is up 1 External PPP Uplink PPP Interface Only val...

Страница 133: ...he syntax External Ethernet Uplink Ports Any value supported by the syntax External Ethernet PPP Layer 2 Uplink Port Any value except down 2 External PPP Uplink HDLC Interface Any value except down 2...

Страница 134: ...rface PPP Uplink HDLC Interface External PPP Uplink PPP Interface PPP Uplink PPP Interface Internal PPP Uplink Ethernet Interface PPP Uplink En Interface Internal Layer 2 Switch PPP Uplink Processor E...

Страница 135: ...k Port enabled 1 or disabled 2 External PPP Uplink HDLC Interface Only valid value is disabled 2 External PPP Uplink PPP Interface Only valid value is disabled 2 Internal PPP Uplink Ethernet Interface...

Страница 136: ...l Ethernet Uplink Port true 1 External Ethernet PPP Layer 2 Uplink Port true 1 External PPP Uplink HDLC Interface false 2 External PPP Uplink PPP Interface false 2 Internal PPP Uplink Ethernet Interfa...

Страница 137: ...0 0 CC SS1 061 Ethernet Uplink Port CC SS1 062 0 0 CC SS1 062 Ethernet PPP Layer 2 Uplink Port CC SS1 070 0 CC SS2 070 CC SS1 070 CC SS3 070 CC SS2 070 0 CC SS3 070 PPP Uplink Ethernet Interface CC S...

Страница 138: ...ch Management Processor Ethernet Interface CC SS1 111 0 0 CC SS1 111 Table C 21 ifStackTable Values 2 of 2 Interface Values CC SSL PPP CC SSL xxx CC SSL yyy ifStackHigherLayer ifStackLowerLayer See if...

Страница 139: ...ence of atmTrafficDescrParamEntry not accessible current No atmVplTable atmMIBObjects 6 Sequence of atmVplEntry not accessible current No atmVclTable atmMIBObjects 7 Sequence of atmVclEntry not access...

Страница 140: ...AdminStatus atmVclEntry 3 AtmVorXAdminStatus read create current Yes atmVclOperStatus atmVclEntry 4 AtmVorXOperStatus read only current Yes atmVclLastChange atmVclEntry 5 AtmVorXLastChange read only c...

Страница 141: ...TM Forum specification AF NM 0095 001 SNMP M4 Network Element View MIB Only the atmfM4TcACellScrambling object part of the atmfM4TcAdapterTable is supported Table C 25 atmfM4PhysPathTpTable Object OID...

Страница 142: ...e C 26 RS 232 MIB Object OID Syntax Access Status Supported rs232Number rs232 1 Integer32 read only current Yes rs232PortTable rs232 2 Sequence of rs232PortEntry not accessible current Yes rs232AsyncP...

Страница 143: ...2PortEntry 6 Integer32 read write current Yes rs232PortInFlowType rs232PortEntry 7 INTEGER read write current Yes rs232PortOutFlowType rs232PortEntry 8 INTEGER read write current Yes Table C 28 rs232A...

Страница 144: ...rtReceiveOverrun Errs rs232SyncPortEntry 5 Counter32 read only current No rs232SyncPortInterrupted Frames rs232SyncPortEntry 6 Counter32 read only current No rs232SyncPortAbortedFrames rs232SyncPortEn...

Страница 145: ...d only current Yes dot3StatsFCSErrors dot3StatsEntry 3 Counter32 read only current Yes dot3StatsSingleCollisionFrames dot3StatsEntry 4 Counter32 read only current Yes dot3StatsMultipleCollisionsFrames...

Страница 146: ...MauBasicGroup 1 Sequence of broadMauBasicEntry not accessible deprecated No Table C 33 ifMauTable Object OID Syntax Access Status Supported ifMauIfIndex ifMauEntry 1 Integer32 read only current Yes if...

Страница 147: ...Pin Modular rj45 2 100BaseTX Gigabit Ethernet Downlink 10BaseT Eight Pin Modular rj45 2 100BaseTX 1000BaseT 100BaseFX Small Form factor Pluggable SFP other 1 1000BaseSX 1000BaseLX Gigabit Ethernet Upl...

Страница 148: ...ssible current Yes adslAturPerfDataTable adslMibObjects 7 adslAturPerfDataEntry not accessible current Yes adslAtucIntervalTable adslMibObjects 8 adslAtucIntervalEntry not accessible current No adslAt...

Страница 149: ...t Yes adslLineAlarmConf Profile adslLineEntry 5 SnmpAdminString read only current No Table C 38 adslAtucPhysTable Object OID Syntax Access Status Supported adslAtucInvSerialNumber adslAtucPhysEntry 1...

Страница 150: ...dslAturCurrStatus adslAturPhysEntry 6 BITS read only current Yes adslAturCurrOutputPwr adslAturPhysEntry 7 INTEGER read only current Yes adslAturCurrAttainableRate adslAturPhysEntry 8 Gauge32 read onl...

Страница 151: ...cess Status Supported adslAturPerfLprs adslAturPerfDataEntry 3 Counter32 read only current Yes adslAturPerfESs adslAturPerfDataEntry 4 Counter32 read only current Yes Table C 44 adslLineConfProfileTab...

Страница 152: ...NTEGER read create current No adslAturConfMinSnrMgn adslLineConfProfileEntry 20 INTEGER read create current No adslAturConfDownshiftSnr Mgn adslLineConfProfileEntry 21 INTEGER read create current No a...

Страница 153: ...Entry not accessible current No adslAturPerfDataExtTable adslMibObjects 20 adslAturPerf DataExtEntry not accessible current Yes adslAturIntervalExtTable adslMibObjects 21 adslAturInterval ExtEntry not...

Страница 154: ...nly current No adslAtucPerfCurr15MinSesL adslAtucPerfDataExtEntry 7 PerfCurrent Count read only current No adslAtucPerfCurr15MinUasL adslAtucPerfDataExtEntry 8 PerfCurrent Count read only current No a...

Страница 155: ...tSesL adslAtucIntervalExtEntry 1 Counter32 read only current Yes adslAturPerfStatUasL adslAtucIntervalExtEntry 2 Counter32 read only current Yes adslAturPerfCurr15MinSesL adslAtucIntervalExtEntry 3 Pe...

Страница 156: ...Access Status Supported dot1dBaseBridgeAddress dot1dBase 1 MacAddress read only mandatory No dot1dBaseNumPorts dot1dBase 2 INTEGER read only mandatory Yes dot1dBaseType dot1dBase 3 INTEGER read only...

Страница 157: ...group is fully supported Table C 52 dot1dStaticTable Object OID Syntax Access Status Supported dot1dStaticAddress dot1dStaticEntry 1 MacAddress read write mandatory Yes dot1dStaticReceivePort dot1dSt...

Страница 158: ...Ports dot1qVlanCurrentEntry 5 PortList read only current No dot1qVlanStatus dot1qVlanCurrentEntry 6 INTEGER read only current No dot1qVlanCreationTime dot1qVlanCurrentEntry 7 TimeTicks read only curre...

Страница 159: ...LinkStatusBadFCSs pppLinkStatusEntry 5 Counter read only mandatory No pppLinkStatusLocalMRU pppLinkStatusEntry 6 INTEGER read only mandatory Yes pppLinkStatusRemoteMRU pppLinkStatusEntry 7 INTEGER rea...

Страница 160: ...supported The mpeDevSelfTestResults object contains the results of self tests for each circuit card assembly separated by semi colons The results are in the format Stack r Chassis r SecProc r Port Pro...

Страница 161: ...MediaConfig pdnNetToMediaGenericMIBObjects 2 ARP Entry Configuration group Yes pdnNetTo8023MediaConfig pdnNetToMediaGenericMIBObjects 3 ARP Entry Configuration for 802 3 Media Cards No ipNetToMediaCon...

Страница 162: ...current Yes ipNetToMediaExtTable ipNetToMediaConfig 3 SEQUENCE OF ipNetToMediaExtEntry not accessible current Yes ipNetToMediaLimitTable ipNetToMediaConfig 4 SEQUENCE OF ipNetToMediaLimitEntry not acc...

Страница 163: ...he Clock Source Group No devConfigTrap pdn devConfig 4 The Trap Configuration Group No devConfigAlarm pdn devConfig 5 The System Alarm Group No devConfigCardType pdn devConfig 6 The Card Type Table No...

Страница 164: ...wareTable pdnControl 5 SEQUENCE OF devSNSwitch FirmwareEntry not accessible current No devControlFTP pdnControl 6 OBJECT IDENTIFIER N A N A Yes devFileXferMIBObjects pdnControl 7 OBJECT IDENTIFIER N A...

Страница 165: ...n Supported pdnVpnConfig pdnIpSec 1 VPN Tunnel Configuration Group Yes pdnIPSecConfig pdnVpnConfigGroups 1 IP Sec Configuration Group Yes pdnIPSecKeyConfig pdnIPSecConfigGroups 1 IP Sec Global Key Con...

Страница 166: ...devSecurityTelnetSource Validation pdn security 6 INTEGER read write mandatory No devSecurityFtpSource Validation pdn security 7 INTEGER read write mandatory No securityMgrTable pdn security 8 SEQUENC...

Страница 167: ...rted by the BitStorm 4800 see Appendix B SNMP Traps PDN DSLAM SYSTEM MIB The PDN DSLAM SYSTEM MIB is used to configure and collect statistics for line cards It comprises the following groups Table C 7...

Страница 168: ...munityTrap AddressInfoTableEntry not accessible current No entCommunityTable sysDevConfig 4 SEQUENCE OF entCommunityTable Entry not accessible current Yes sysDevUserAccountTable sysDevConfig 5 SEQUENC...

Страница 169: ...ysDevFilter Group Object OID Syntax Access Status Supported sysDevSNInjectionType sysDevFilter 1 Integer not accessible mandatory No sysDevSNInjectionVnid sysDevFilter 2 VnidRange not accessible manda...

Страница 170: ...xIp Subnets pdnInetMIBObjects 4 Integer32 read only current No pdnInetIpAddressTable CurrentIpSubnets pdnInetMIBObjects 5 Integer32 read only current No pdnInetIpAddressTable pdnInetMIBObjects 6 SEQUE...

Страница 171: ...and time using SNTP The devNTP group is fully supported Table C 78 PDN SYSLOG MIB Objects Object OID Syntax Access Status Supported pdnSyslogStatus pdnSyslog 1 INTEGER read write current Yes pdnSyslo...

Страница 172: ...C MIB Support C 60 July 2002 4800 A2 GB20 10...

Страница 173: ...adslAturPerfDataTable 1 3 6 1 2 1 10 94 1 1 7 ADSL Line MIB RFC 2662 adslAturPhysTable 1 3 6 1 2 1 10 94 1 1 3 ADSL Line MIB RFC 2662 adslConfProfileExtTable 1 3 6 1 2 1 10 94 3 1 22 ADSL Line Extens...

Страница 174: ...ackTable 1 3 6 1 2 1 26 2 2 802 3 MAU MIB RFC 2668 ifMauAutoNegTable 1 3 6 1 2 1 26 5 1 802 3MAU MIB RFC 2668 ifMauTable 1 3 6 1 2 1 26 2 1 802 3 MAU MIB RFC 2668 ifNumber 1 3 6 1 2 1 2 1 Interfaces G...

Страница 175: ...2 24 2 35 1 1 mpe_sensor mpeSysDevDslamMIBTraps 1 3 6 1 4 1 1795 2 24 12 24 2 mpe_dslam pdn_security 1 3 6 1 4 1 1795 2 24 2 8 pdn_security pdnAtmStat 1 3 6 1 4 1 1795 2 24 2 6 11 3 3 pdn_AtmStats pdn...

Страница 176: ...1 2 1 11 5 MIB for SNMPv2 RFC 1907 snmpInBadVersions 1 3 6 1 2 1 11 3 MIB for SNMPv2 RFC 1907 snmpInPkts 1 3 6 1 2 1 11 1 MIB for SNMPv2 RFC 1907 snmpProxyDrops 1 3 6 1 2 1 11 32 MIB for SNMPv2 RFC 1...

Страница 177: ...figure date DateAndTime devConfigTimeOfDay pdn_Config Configure date timezone Time zone devConfigTimeOfDay pdn_Config Configure factory Default nvram settings pdnCCMOperation pdn_control Configure fil...

Страница 178: ...nfigure interface console data bits DataBits rs232AsyncPortBits RFC 1659 Configure interface console parity Parity rs232AsyncPortParity RFC 1659 Configure interface console rate Speed rs232PortOutSpee...

Страница 179: ...slAtucChanConfInterleaveMinTx Rate ADSL Line Mib Configure interface dsl minimum margin Minimum Margin adslAturMinSnrMargin ADSL Line Mib Configure interface dsl min upstream speed Minimum Uprate for...

Страница 180: ...Link Type rs232PortType RFC 1659 Configure interface v35 rate Speed rs232PortOutSpeed RFC 1659 Configure ip nhr ip address ip address ipNetToMediaDefaultNHR pdn_Arp MIB Configure management gateway g...

Страница 181: ...Configure management connection modify encryption encryption pdnIPSecConnectionIPSecESP InboundEncryptionAlg OR pdnIPSecConnectionIPSecESP OutboundEncryptionAlg pdn_IpSecManual mib Configure manageme...

Страница 182: ...string communityName and communityType pdn_dslam Configure management snmp public string Public community string entCommunityName and entCommunityType pdn_dslam Configure management snmp state state...

Страница 183: ...RateLimiting pdn_syslog Configure syslog threshold Syslog threshold pdnSyslogSeverityThreshold pdn_syslog Configure system information system location System Location sysLocation RFC 1213 Configure sy...

Страница 184: ...e username pdnDevFileXferUserName pdn_control Firmware download status status pdnDevFileXferStatus pdn_control firmware revision revision devFirmwareControlRelease pdn_control firmware switch switch d...

Страница 185: ...rface dsl latency Latency adslLineType ADSL Line MIB Show interface dsl link Oper state ifOperStatus MIB II Show interface dsl atm data connection VCI VCI atmVclVci Atm Management Objects MIB Show int...

Страница 186: ...Line MIB Show interface dsl statistics down SES Down Severely Error Seconds SES adslAturPerfStatSesL Ext to ADSL Line MIB Show interface dsl statistics down UAS Down Unavailable Error Seconds UAS adsl...

Страница 187: ...Speed rs232PortOutSpeed RFC 1659 Show interface modem parity Parity rs232AsyncPortParity RFC 1659 Show interface modem stop bits StopBits rs232AsyncStopBits RFC 1659 Showinterfacemodemuptime Current...

Страница 188: ...on default encryption encryption pdnUsrIpSecKeySetupAlg pdn_IpSecManual mib Show management connection default esp alg esp alg pdnUsrIpSecKeySetupAlg pdn_IpSecManual mib Show management connection def...

Страница 189: ...anual mib Show management connection modify spi spi pdnIPSecConnectionIPSecAH InboundSPI OR pdnIPSecConnectionIPSecAH OutboundSPI OR pdnIPSecConnectionIPSecESP InboundSPI OR pdnIPSecConnectionIPSecESP...

Страница 190: ...utoBackupDynamicTime pdn_Control Show security ip address Ip address ipNetToMediaNetAddress RFC 2011 Show security ip interface interface ifIndex RFC 1213 Show security ip max ip Max ip addresses ipNe...

Страница 191: ...sion entPhysicalHardwareRev RFC 2737 Show system revisions description Unit description sysDescr RFC 1213 Show system revisions location Unit location sysLocation RFC 1213 Show system revisions main c...

Страница 192: ...Show system status fan2 Fan2 fanModuleFailure Trap pdn_dslam Show system status fan3 Fan3 fanModuleFailure Trap pdn_dslam Show system status selftest selftest mpeDeviceSelfTestFailure Trap mpe_Health...

Страница 193: ...s line line loginAccessApp pdn_dslam Show users location location loginAccessHost pdn_dslam Show vlans hardware address hardware address dot1qTpFdbAddress RFC 2674 MIB Show vlans port id port id dot1q...

Страница 194: ...E CLI to MIB Object Cross Reference E 18 July 2002 4800 A2 GB20 10...

Страница 195: ...arizona GMT 7 No Daylight Savings Time us pacific GMT 8 Subject to U S Daylight Savings Time Rules us alaska GMT 9 Subject to U S Daylight Savings Time Rules us aleutian GMT 10 Subject to U S Daylight...

Страница 196: ...o British Daylight Savings Time Rules europe western GMT Subject to Western European Daylight Savings Time Rules europe central GMT 1 Subject to Central European Daylight Savings Time Rules europe eas...

Страница 197: ...s Time Rules libya GMT 2 Subject to Libyan Daylight Savings Time Rules japan GMT 9 No Daylight Savings Time korea GMT 9 Subject to Korean Daylight Savings Time Rules singapore GMT 8 No Daylight Saving...

Страница 198: ...e 0A00 0201 PUP Addr Trans see 0A01 0400 Nixdorf 0600 XEROX NS IDP 0660 DLOG 0661 DLOG 0800 Internet IP IPv4 0801 X 75 Internet 0802 NBS Internet 0803 ECMA Internet 0804 Chaosnet 0805 X 25 Level 3 080...

Страница 199: ...Ungermann Bass download 7002 Ungermann Bass dia loop 7020 7029 LRT 7030 Proteon 7034 Cabletron 8003 Cronus VLN 8004 Cronus Direct 8005 HP Probe 8006 Nestar 8008 AT T 8010 Excelan 8013 SGI diagnostics...

Страница 200: ...5 Univ of Mass Amherst 8066 Univ of Mass Amherst 8067 Veeco Integrated Auto 8068 General Dynamics 8069 AT T 806A Autophon 806C ComDesign 806D Computgraphic Corp 806E 8077 Landmark Graphics Corp 807A M...

Страница 201: ...an Associates 80DE 80DF Integrated Solutions TRFS 80E0 80E3 Allen Bradley 80E4 80F0 Datability 80F2 Retix 80F3 AppleTalk AARP Kinetics 80F4 80F5 Kinetics 80F7 Apollo Computer 80FF 8103 Wellfleet Commu...

Страница 202: ...1EF Polygon 81F0 81F2 Comsat Labs 81F3 81F5 SAIC 81F6 81F8 VG Analytical 8203 8205 Quantum Software 8221 8222 Ascom Banking Systems 823E 8240 Advanced Encryption Syste 827F 8282 Athena Programming 826...

Страница 203: ...2 F 9 8A96 8A97 Invisible Software 9000 Loopback 9001 3Com Bridge XNS Sys Mgmt 9002 3Com Bridge TCP IP Sys 9003 3Com Bridge loop detect FF00 BBN VITAL LanBridge cache FF00 FF0F ISC Bunker Ramo Table F...

Страница 204: ...F Reference Tables F 10 July 2002 4800 A2 GB20 10...

Страница 205: ...on 3 3 automatic logout 3 5 command descriptions A 1 help 3 4 keyboard definitions 3 5 Command Line Interface CLI continued prompts 3 2 syntax error 3 5 using 3 1 commands automatic completion 3 3 CLI...

Страница 206: ...sages 5 3 syntax 3 5 Ethernet ports configuring A 17 MIB C 57 naming conventions 2 3 Ethernet Like MIB C 33 F factory defaults restoring A 7 features 1 1 1 3 filter binding A 9 configuring A 8 rule A...

Страница 207: ...PDN HEADER MIB C 7 PDN INET CONFIG MIB C 58 PDN MPE DSLAM SYSTEM MIB C 48 PDN MPE ENTITY SENSOR MIB C 48 PDN MPE HEALTH AND STATUS MIB C 48 PDN SECURITY MIB C 54 PDN STACKABLE MIB C 59 PDN SYNCPORTST...

Страница 208: ...estart A 51 special keys 3 5 statistics A 52 DSL A 57 Ethernet A 59 V 35 X 21 A 61 Status screen cross reference 5 6 syntax error 3 5 sysDescr C 5 sysObjectID C 6 System Group C 5 system information c...

Отзывы: