Maintenance
4-32
3160-A2-GB21-80
March 1999
The Test Started screen appears.
F1
Send:
Name and Dest
Test Started
F2
F3
If the DSU/CSU is already sending the test pattern you selected, the
message
Already active
appears. If you selected an incompatible test
pattern combination, the message
Invld Test Combo
appears. See
Table 4-9 for valid combinations.
Table 4-9.
Valid Send Test Pattern Combinations
QRSS
(Network)
QRSS (Port)
1-in8
(Network)
511 (Port)
QRSS
(Network)
N/A
NO
NO
NO
QRSS (Port)
NO
YES (on
separate ports)
N/A
YES (on
separate ports)
1 in 8
(Network)
NO
NO
N/A
NO
511 (Port)
NO
N/A
N/A
YES (on
separate ports)