Maintenance
4-11
3160-A2-GB21-80
March 1999
Alarms
The DSU/CSU can be attached, either locally or remotely, to an ASCII terminal or
printer to display or print alarm messages. Alarms can also be displayed on a PC
that is using a terminal emulation package.
For standalone DSU/CSUs, you can route these alarms to the MODEM port, the
COM port, or both. For carrier-mounted DSU/CSUs, you can route them to the
COM port or dial them out using an external device.
Each alarm message contains a customer identification to indicate which remote
DSU/CSU is reporting an alarm. For information about customer identification,
refer to
Displaying Unit Identity
in Chapter 3,
Operation.
Possible alarm messages are as follows:
Continuous Loss Of Signal detected at the
x Interface
(where
x is either Network or DTE).
Alarm Cleared. Loss Of Signal condition at the
x
Interface
(where
x is either Network or DTE).
Continuous Out Of Frame condition detected at the
x
Interface
(where
x is either Network or DTE).
Alarm Cleared. Out Of Frame condition at the
x Interface
(where
x is either Network or DTE).
Alarm Indication Signal received at the
x Interface
(where
x is either Network or DTE).
Alarm Cleared. Alarm Indication Signal at the
x Interface
(where
x is either Network or DTE).
An Excessive Error Rate has been detected at the Network
Interface
.
Alarm Cleared. An Excessive Error Rate at the Network
Interface
.
Yellow Alarm signal received at the
x Interface
(where
x is
either Network or DTE).
Alarm Cleared. Yellow Alarm signal at the
x Interface
(where
x is either Network or DTE).
Continuous Out Of Frame condition detected at synchronous
data port
n
(where
n is the port number).
Alarm Cleared. Out Of Frame condition at synchronous data
port
n
(where
n is the port number).
An Excessive Error Rate has been detected at synchronous
data port
n
(where
n is the port number).
Alarm Cleared. An Excessive Error Rate at synchronous
data port
n
(where
n is the port number).
Содержание ACCULINK 3160
Страница 1: ...ACCULINK 3160 3161 3164 AND 3165 DSU CSU OPERATOR S GUIDE Document No 3160 A2 GB21 80 March 1999...
Страница 16: ...About This Guide x 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 24: ...Introduction 1 8 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 100: ...Operation 3 66 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 140: ...Maintenance 4 38 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 141: ...A 1 3160 A2 GB21 80 March 1999 Front Panel Menu A...
Страница 278: ...Asynchronous Terminal Operation H 24 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 280: ...Equipment List I 2 3160 A2 GB21 80 March 1999 This page intentionally left blank...