Operation
3-12
3160-A2-GB21-80
March 1999
Selecting the DTE Drop/Insert or Data Port for LED
Display
Use the LED command on the Control branch to select which port’s (DTE
Drop/Insert or data port) status appears on the five shared LEDs on the front
panel.
Procedure
To select a port for LED display:
1. From the top-level menu screen, press the
key until the Ctrl selection
appears on the screen.
2. Select Ctrl.
3. From the Control screen, select LED.
F1
Control:
Call
Rel
LED
F2
F3
The currently selected port name appears on the top line of the LCD. DTE
indicates the DTE Drop/Insert (DSX-1) port.
F1
LED Dsply: DTE
DTE
Prt1
Prt2
F2
F3
4. From the LED Dsply screen, press the Function key that corresponds to the
DTE Drop/Insert (DSX-1) or data port for which you want the LEDs to display.
Use the scroll keys, if necessary.
Select DTE to monitor the DTE Drop/Insert (DSX-1) port’s SIG, OOF, ALRM,
PDV, and BPV status signals on the shared LEDs.
Select a particular data port to monitor the data port’s DTR, TXD, RXD, CTS,
and RTS control signals on the shared LEDs.
Содержание ACCULINK 3160
Страница 1: ...ACCULINK 3160 3161 3164 AND 3165 DSU CSU OPERATOR S GUIDE Document No 3160 A2 GB21 80 March 1999...
Страница 16: ...About This Guide x 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 24: ...Introduction 1 8 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 100: ...Operation 3 66 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 140: ...Maintenance 4 38 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 141: ...A 1 3160 A2 GB21 80 March 1999 Front Panel Menu A...
Страница 278: ...Asynchronous Terminal Operation H 24 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 280: ...Equipment List I 2 3160 A2 GB21 80 March 1999 This page intentionally left blank...