Installation
2-6
3160-A2-GB21-80
March 1999
1
2
3
4
5
6
BLACK
RED
GREEN
WHITE
ORANGE
BLUE
GROUND
+ 24 VDC RETURN
+ 24 VDC SOURCE
99-14298-02
X
X
X
DSU/CSU POWER
PLUG
TO CUSTOMER-SUPPLIED BATTERY
Figure 2-9.
+24 Vdc Power Supply Pinouts
Installing the Single –
48 Vdc Power Supply
To install the DSU/CSU using a single source – 48 Vdc SELV power supply, refer
to
Figure 2-10
and use the following procedure.
Procedure
To install the – 48 Vdc single source power supply:
1. Connect the black and red wires to the – 48 Vdc return source.
2. Connect the green wire to a suitable ground.
3. Connect the orange and blue wires to the –
48 Vdc input source.
4. Cut the white wire off at the outer insulation.
5. Plug the power connector into the DSU/CSU.
1
2
3
4
5
6
BLACK
RED
GREEN
WHITE
ORANGE
BLUE
– 48 VDC INPUT
99-14299-02
X
GROUND
DSU/CSU POWER
PLUG
TO CUSTOMER-SUPPLIED BATTERY
– 48 VDC RETURN
Figure 2-10.
– 48 Vdc Single Source Power Supply Pinouts
Содержание ACCULINK 3160
Страница 1: ...ACCULINK 3160 3161 3164 AND 3165 DSU CSU OPERATOR S GUIDE Document No 3160 A2 GB21 80 March 1999...
Страница 16: ...About This Guide x 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 24: ...Introduction 1 8 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 100: ...Operation 3 66 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 140: ...Maintenance 4 38 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 141: ...A 1 3160 A2 GB21 80 March 1999 Front Panel Menu A...
Страница 278: ...Asynchronous Terminal Operation H 24 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Страница 280: ...Equipment List I 2 3160 A2 GB21 80 March 1999 This page intentionally left blank...