Setup: Item Settings
181
S
e
tu
p
This menu sets the time code.
•
XX
indicates factory default settings.
TIME CODE
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
500
VITC BLANK
0000
0001
BLANK
THRU
Specifies whether or not a VITC signal will be output at the positions selected in setup
menu No. 501 (VITC POS-1) and No. 502 (VITC POS-2) during playback.
0: VITC signals are not output.
1: VITC signals are output.
NOTE:
• This setting is available only during analog composite output and SD SDI output.
• In EE mode, the input signal is output with the VITC signal.
501
VITC POS-1
When set to
59.94 Hz, 29.97 Hz
Specifies the position where the VITC signal will be inserted.
NOTE:
• You cannot select the same line as in setup menu No. 502 (VITC POS-2).
• The VITC signal is not output when 23.98, 24, 59-23, 60-24, or 60-25 is selected in
setup menu No.25 (SYSTEM FREQ).
• You cannot select the same line as in setup menu No.692 (UMID POS).
• This setting is available only during analog composite output and SD SDI output.
• This setting does not return to factory default even if you press the SEARCH button
and RESET button simultaneously.
0000
|
0006
|
0010
10L
|
16L
|
20L
When set to
50 Hz, 25 Hz
0000
|
0004
|
0015
7L
|
11L
|
22L
502
VITC POS-2
When set to
59.94 Hz, 29.97 Hz
Specifies the position where the VITC signal will be inserted.
NOTE:
• You cannot select the same line as in setup menu No. 501 (VITC POS-1).
• The VITC signal is not output when 23.98, 24, 59-23, 60-24, or 60-25 is selected in
setup menu No.25 (SYSTEM FREQ).
• You cannot select the same line as in setup menu No.692 (UMID POS).
• This setting is available only during analog composite output and SD SDI output.
• This setting does not return to factory default even if you press the SEARCH button
and RESET button simultaneously.
0000
|
0008
|
0010
10L
|
18L
|
20L
When set to
50 Hz, 25 Hz
0000
|
0006
|
0015
7L
|
13L
|
22L
504
RUN MODE
0000
0001
REC
FREE
Specifies an operating mode that advances the internal time code generator.
0: The internal time code generator is advanced only during recording.
1: When the power is on, the internal time code generator is advanced regardless of
operating mode.
NOTE:
When setup menu No. 040 (VFR REC) is set to ON, the time code advances only during
recording even when FREE is selected.
59.94Hz
50Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
29.97Hz
25Hz
only