![background image](http://html1.mh-extra.com/html/omron/v530-r150e-2/v530-r150e-2_operation-manual_741960079.webp)
4-5
Section
Connection Examples
67
Connection 4
The wiring required between the host and the NT-AL001 is
shown below.
Host
NT-AL001
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
Pin No.
:
:
:
:
:
Meaning
Send data
Receive data
Request to send
Clear to send
Power supply (+5 V)
Signal ground
5 V
power
supply
Pin No.
2
3
4
5
6
9
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
+5 V
SG (GND)
V530-R150 Settings
1
Go into system mode and select
multi drop.
SET
MON
RUN
SYS
SAVE
––––
–––ms
Communications
Image storage
Startup mode
Error method
Version
Backup
System settings
Multi drop
2
The following screen will be displayed. Set each of the dis-
played items.
Set this to “ON.”
Set the unit number (00 to 31).
Settings
Unit number
End
3
Select
End.