background image

 

DS4600A 

Laser Barcode Reader 

Quick Reference Guide

 

The scanner is classified as a Class 2 laser 
product according to EN 60825-1 regulations 
and as a Class II laser product according to 
CDRH regulations. 
 
For installation, use and maintenance it is not 
necessary to open the device. 
 
There is a safety device which allows the 
laser to be switched on only if the motor is 
rotating above the threshold for its correct 
scanning speed. 
 
The laser beam can be switched off through a 
software command (see also the WinHost 
Help On-Line).  

      

Figure A 

Cable with 25-pin Connector

Laser Beam Output Window

Warning Label

Mounting Holes

Accessory Mounting Holes

Data TX LED

Good Read LED

Ready LED

External Trigger LED

Warning and Classification Labels

1

2

3

4

5

6

7

10

8

9

Keypad

11

Display

12

 

DATALOGIC S.p.A. Via Candini, 2
40012 LIPPO DI CALDERARA (BO) ITALY

Model No.

Serial No.

Volt

Amp.

Manufactured

This product conforms to the applicable requirements of
21CFR1040 at the date of manufacture.

 

LASER LIGHT

DO NOT STARE INTO BEAM

CLASS 2 LASER PRODUCT

MAXIMUM OUTPUT RADIATION  1 mW
EMITTED WAVE LENGTH  630~680 nm

TO IEC 825-1 (1993)

  

Warning and device class labels

 

For further details on product installation, see the 
complete Installation Manual available on the WinHost 
CD included with this product. 
 
POWER SUPPLY 

-  This product is intended to be installed by Qualified 

Personnel only. 

The laser diode used in this device is classified 
as a class 3B laser product according to EN 
60825-1 regulations and as a Class IIIb laser 
product according to CDRH regulations. As it is 
not possible to apply a classification label on 
the laser diode used in this device, the 
following label is reproduced below. 

- Models 

DS4600A-XXX0: 

This device is intended to be supplied by a UL Listed 
Direct Plug-in Power Unit marked “Class 2”, rated 10-30 
V minimum, 0.60 A. 
This device may also be supplied by a UL Listed Power 
Unit marked “Class 2” or LPS power source which 
supplies power directly to the scanner via the 25-pin 
connector. 

- Model 

DS4600A-2XX5: 

This device is intended to be supplied by a UL Listed 
Direct Plug-in Power Unit marked “Class 2”, rated 24 V 
minimum, 0.50 A. 
This device may also be supplied by a UL Listed Power 
Unit marked “Class 2” or LPS power source which 
supplies power directly to the scanner via the 25-pin 
connector. 

 

LASER LIGHT

AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT

MAX. OUTPUT RADIATION  30 mW

EMITTED WAVE LENGTH  630~680 nm

TO IEC 825-1 (1993)

 

Laser diode class label 

Any violation of the optic parts in particular 
can cause radiation up to the maximum level 
of the laser diode (30 mW at 630 to 680 nm). 

DS4600A - 2XXX Models

 

10 

4

2

3

11 

12

2

DS4600A - 3XXX Models

Summary of Contents for DS4600A

Page 1: ...vailable on the WinHost CD included with this product POWER SUPPLY This product is intended to be installed by Qualified Personnel only The laser diode used in this device is classified as a class 3B...

Page 2: ...e RS232 RS485 Full Duplex Half Duplex 20 mA C L only with INT 24 accessory Code 128 EAN 128 Code 93 Codabar Auxiliary Interface RS232 Pharmacode Baudrates 1200 to 115200 Inputs Headers and Up to four...

Page 3: ...cted to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout Pin Name Function 13 VS Power supply input voltage 25 GND...

Page 4: ...s Input Output Connections Open Collector USER INTERFACE 8 11 12 22 DS4600A 25 pin Vext 40 Vdc max C E Output open collector connections VCE max 40 Vdc I max 40 mA continuous NPN NPN 5V DS4600A 25 pin...

Page 5: ...ial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave...

Page 6: ...300 400 mm 24 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 200X Medium Range CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle...

Page 7: ...200 220 240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 280 11 0 20 mm 8 mils 0 30 mm 12 mils DS4600A 22XX Short Range CONDITIONS Test Codes used Interleaved 2 5 and Code 39 PCS 0 90 Pitch ang...

Page 8: ...0 450 500 550 mm 250 200 150 100 50 0 50 100 150 200 250 mm 20 22 0 25 mm 10 mils 0 30 mm 12 mils 0 50 mm 20 mils 8 10 DS4600A 2X2X Raster R2 CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch...

Page 9: ...4 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 30XX Medium Range CONDITIONS Code Interleaved 2 5 and Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt ang...

Page 10: ...itch angle 0 Skew angle 15 Tilt angle 0 SW Resolution High Parameter selectable in WinHost 4 2 0 2 10 8 6 4 6 8 10 in 0 2 6 4 20 12 in 8 10 14 16 18 0 40 80 120 160 200 240 280 320 360 400 440 480 520...

Page 11: ...CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagrams show a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D sub...

Page 12: ...elating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etates membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gese...

Reviews: