3-1
Section
Specifications
24
There are 3 kinds of COM OUT (*1 to *3) for each output terminal.
Connect with reference to the following table.
A
Top
Bottom
+
Power supply
NC
Not connected
–
o e su
y
Appropriate ground
RUN
Control output
ERR
Error output
BUSY
Co
o ou u
GATE
Control output
OK/NG
Judgment output
NC
Not connected
COM OUT
(*1)
For RUN, ERR, BUSY,
GATE, and OK/NG
RESET
Restart
DSA
Prohibited to use
TRIG A
Trigger input (One shot
mode)
COM IN
TRIG B
Trigger input (Continuous or
Level Trigger mode)
B
Top
Bottom
DO 1
Coincidence output
DO 0
Coincidence output
DO 3
Co c de ce ou u
DO 2
Co c de ce ou u
DO 5
Prohibited to use
DO 4
Prohibited to use
DO 7
o b ed o use
DO 6
o b ed o use
NC
Not connected
COM OUT
(*2)
For DO 0 to DO7
DO 9
Prohibited to use
DO 8
Prohibited to use
DO 11
o b ed o use
DO 10
o b ed o use
DO 13
DO 12
DO 15
DO 14
COM OUT
(*3)
For DO 8 to DO15
Note
1. Do not reverse the connections of the signal terminals and
COM terminals.
2. Do not use RESET input immediately after power is turned
ON.
When using RESET input to synchronize execution timing,
wait at least 1 s after turning ON the V530-R150 power sup-
ply before turning ON the RESET terminal.