6-1
Section
SET (Setting) Mode
124
Normal Procedure
1
Select
Read DM (Normal).
2. Image Analysis
0. Image Adjust (DM)
1. Read DM (Normal)
2
Select
Reading Settings (Manual).
Reading Settings (Teaching)
Function Settings
Reading Settings (Manual)
Display Settings
3
Set the items as required.
Symbol Color
:
Black
j
Right &Left Reverse
:
OFF
j
Code Size 1
: 10
10
j
Code Size 2
:
None
j
Number of Retries
:
0
j
Free Finder Length
:
OFF
j
Length of Finder
:
[179]
Background Cut
:
Weak
j
4
Select
Register to validate the settings and leave this win-
dow.
<Observe the following points for Data Matrix reading in Normal mode>
1
Set the filtering method to weak or strong smoothing.
2
Turn ON the filtering retry function if necessary.
3
If the code is white symbol printed on black base, set the
background cut level to middle or strong.