![background image](http://html1.mh-extra.com/html/omron/v530-r150e-2/v530-r150e-2_operation-manual_741960044.webp)
3-3
Section
Timing Chart
31
3-3-3
Reading Level Trigger (when trigger mode is
“Level Trigger”)
OK judgment (Readable)
Enter RUN mode
Leave RUN mode
RUN
TRIG B
BUSY
OK/NG
DO 0 to 3
GATE
(RS-232C)
Reading
(OK)
Judgment (OK)
Coincidence judgment
Gate ON
delay
Gate ON
time
Output period
*Delay of 33.3 ms max. occurs before starting to
load images after TRIG B signal is turned ON.
Note The output time to RS-232C changes according to the data vol-
ume and baud rate.
Output Terminals
The same as continuous mode.
Input Terminals
Terminal
Function
TRIG B
Continuous reading is performed while TRIG B signal is turned ON until
OK (readable) reading judgment is output.