6-1
Section
SET (Setting) Mode
135
Procedure
1
Select
DM (Pattern).
2. Image Analysis
0. Image Adjust
1. Read DM (Pattern)
2
Select
Reading Settings.
Pattern Settings
Function Settings
Reading Settings
Display Settings
3
Set the items as required.
Symbol Color
:
Black
j
Right &Left Reverse
:
OFF
j
Code Size
: 10
10
j
Number of Retries
:
0
j
Endpoint Calculation
:
ON
j
Search Interval
:
[4]
Correlation
:
[30]
4
Select
Register to validate the settings and leave this win-
dow.
<Observe the following points for Data Matrix reading in Pattern mode>
1
Set the filtering method to weak or strong smoothing.
2
If there is enough time available, set the number of retries to
a value between 1 and 9.
3
Adjust the field of vision for the Camera so that there are at
least 10 pixels per cell.