2-3
Section
Power Supply and Ground
11
2-3-3
Wiring the Power Supply
Caution
Use a DC power supply with safe extra low-voltage circuits on
the secondary side. Excessively high voltages can result in elec-
tric shock.
Power supply
Use a power supply with the following specifications. We recom-
mend using OMRON’s S82K-01524 Power Supply.
Output current
0.6 A min.
Power supply voltage
24 VDC+10%, –15%
Use a power supply with the following specifications when con-
necting the V530-R150 and F150-M05L LCD Monitor to one
power supply. We recommend using OMRON’s S82K-05024
Power Supply.
Output current
1.6 A min.
Power supply voltage
24 VDC+10%, –15%
24 VDC
Note
1. Wire the Power Supply Unit independently of other devices.
In particular, keep the power supply wired separately from
inductive loads.
2. Keep the power supply cable as short as possible.
3. If UL recognition is required, use a UL class II power supply.