4-5
Section
Connection Examples
59
Communication Settings
•
V530-R150
→
Item
Setting
Baud rate
19200 bps
Data length
8 bit
Parity bits
EVEN
Stop bits
2 bit
Header
None
Footer
CR
Mode
Normal
•
Programmable Controller:
Turn OFF the DIP switch of CQM1.
Set DM6645 to [1001], DM6646 to [0904], DM6648 to [1000]
and DM6649 to [0D00].
Match communication settings with the V530-R150. Refer to
the operation manual for CQM1 for the ways to change the set-
ting.
Program Examples
This is an example of a program in which a Programmable Con-
troller (CQM1) receives the data which is read at a V530-R150.
1
Set the reading conditions of the V530-R150 and set the
reading mode to RUN mode.
2
The synchronous sensor or trigger input of the console
sends the reading trigger to the V530-R150.
→
The V530-R150 reads the code and outputs data.