6-1
Section
SET (Setting) Mode
122
1. Read DM (Normal)
Reading Settings (Manual)
Set the various reading condition parameters. This menu can
also be used to view or change parameters set using the teach-
ing function.
Note “Length of Finder” is the length of the finder patterns for the code
expressed in pixel units. The V530-R150 detects finder patterns
that correspond to this length and performs readings. “Free
Finder Length” is a function that is used when there are several
different sizes of reading codes, with large differences in the
length of the finder. If this function is turned ON, any finder pat-
terns at least as long as the value set as the “Length of Finder”
will be detected and reading performed.
Symbol Color
:
Black
j
Right &Left Reverse
:
OFF
j
Code Size 1
: 10
10
j
Code Size 2
:
None
j
Number of Retries
:
0
j
Free Finder Length
:
OFF
j
Length of Finder
:
[179]
Background Cut
:
Weak
j
*:
Indicates items set automatically using the teaching function.
*
A
*
B
G
*
F
E
D
C
1
Select the color of symbol.
Black
(Default
setting)
Black symbol printed on white base.
White
White symbol printed on black
base.
Auto
Automatically determines the appropriate symbol
color. Use this setting when reading codes that
include both symbol colors. If, however, the
symbol color is known to be one or the other
(i.e., either black or white), set to black or white to
reduce the required processing time.