4-2
Section
Communication Settings
43
The V530-R150 automatically reads these commands, exe-
cutes them, and writes any judgments to the Write Area.
Unit No.: 00 (fixed)
Checks Read Area
for a command.
Returns command.
The rest of the operation
is not performed if the
command format is incor-
rect.
Command sent to
clear Read Area.
Read Area cleared.
Executes command.
Terminal block BUSY terminal turned ON during readings.
Command re-
quires output of
judgments?
No
Yes
Writes data to Write
Area.
Returns write completed
response.
A timeout error occurs if there is no response within 5 s.
An error message appears on the screen and the ERR (error) terminal
turns ON.