4-2
Section
Communication Settings
41
4-2
Communication Settings
4-2-1
Normal Communications Mode
If the Normal communications mode is selected, data can be out-
put in normal format to an external device via the RS-232C port.
Communications method setting menu
→
I/O via the RS-232C Port
Input command
Execute command
The BUSY terminal turns ON while readings are being performed.
Output judgment
Gate ON time varies according to data vol-
ume and baud rate.
Receive judgment
V530
Host computer
A timeout error occurs if there is no response from the host com-
puter within the set time when RS/CS or Xon/off is selected for
flow control. An ERR (error) message appears on the screen,
and the error terminal turns ON.
Program example
→