6-4
Section
System
164
5
ON:
Checks the mode of the Programmable Controller in
MON (monitor) and RUN modes. Reading starts
with MON (monitor) mode. Error messages are dis-
played.
(Default setting)
OFF: Sends the command to switch mode to the Program-
mable Controller in MON (monitor) and RUN modes
and switch the mode to MON (monitor) mode forci-
bly.
Terminal Block
ON state
Gate ON delay
Gate ON time
NG: ON
A
B
C
D
E
1
Select a trigger mode for TRIG B.
Continuous
(Default)
Performs continuous reading while the TRIG B
terminal is turned ON. In this mode, the settings
for reading accuracy and the number of retries
are invalid with TRIG B input.
Level trig
(trigger)
Repeats reading until an OK (readable) reading
judgment is output while the TRIG B terminal is
ON. In the case of an NG (not readable)
reading, the NG signal is output when the TRIG
B is turned OFF.
2
Select whether the OK/NG terminal is turned ON for an OK
reading or an NG reading. (The default is ON for NG.)
3
Set the output period for reading judgment. Set a value be-
tween 2.0 and 10000.0 ms that is greater than the rising time
+ output time, and less than the reading interval. If the cycle
is longer than the reading interval, the output timing will fall
behind as the readings are repeated.
(The default setting is 10.0 ms.)
4
Set the time from when the result is output to the terminal
block to when the GATE signal is turned ON. This time is