4-5
Section
Connection Examples
62
Program Examples
A command (reading trigger) is sent to the V530-R150 and the
data received at the V530-R150 is written to the specified words
of the Programmable Controller.
1
Set the reading conditions of the V530-R150 and set the
reading mode to RUN mode.
2
Set the reading start command [0010] to DM0100.
3
The Programmable Controller sends the reading start com-
mand.
→
The V530-R150 reads codes and writes to DM0111.
4
The Programmable Controller checks if the data has been
written by checking the writing flag [DM0110].
00101 turns ON when the input
00001 is ON.
Sends the set command to
DM0100 (reading trigger).
Checks the write completed flag
DM0110. 00102 turns ON when
writing (receiving) is completed.
(
Perform the necessary procedure.)
Clears the write completed flag.